Model selection for radiochromic film dosimetry.

I Méndez1.   

Abstract

The purpose of this study was to find the most accurate model for radiochromic film dosimetry by comparing different channel independent perturbation models. A model selection approach based on (algorithmic) information theory was followed, and the results were validated using gamma-index analysis on a set of benchmark test cases. Several questions were addressed: (a) whether incorporating the information of the non-irradiated film, by scanning prior to irradiation, improves the results; (b) whether lateral corrections are necessary when using multichannel models; (c) whether multichannel dosimetry produces better results than single-channel dosimetry; (d) which multichannel perturbation model provides more accurate film doses. It was found that scanning prior to irradiation and applying lateral corrections improved the accuracy of the results. For some perturbation models, increasing the number of color channels did not result in more accurate film doses. Employing Truncated Normal perturbations was found to provide better results than using Micke-Mayer perturbation models. Among the models being compared, the triple-channel model with Truncated Normal perturbations, net optical density as the response and subject to the application of lateral corrections was found to be the most accurate model. The scope of this study was circumscribed by the limits under which the models were tested. In this study, the films were irradiated with megavoltage radiotherapy beams, with doses from about 20-600 cGy, entire (8 inch  × 10 inch) films were scanned, the functional form of the sensitometric curves was a polynomial and the different lots were calibrated using the plane-based method.

Mesh:

Year:  2015        PMID: 25928128     DOI: 10.1088/0031-9155/60/10/4089

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.

Authors:  David F Lewis; Maria F Chan
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Detectors assessment for stereotactic radiosurgery with cones.

Authors:  Nicolas Garnier; Régis Amblard; Rémy Villeneuve; Rodolphe Haykal; Cécile Ortholan; Philippe Colin; Anaïs Gérard; Sarah Belhomme; Franck Mady; Mourad Benabdesselam; Benjamin Serrano
Journal:  J Appl Clin Med Phys       Date:  2018-09-14       Impact factor: 2.102

3.  Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams.

Authors:  Andreas F Resch; Fatima Padilla Cabal; Milovan Regodic; Wolfgang Lechner; Gerd Heilemann; Peter Kuess; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2022-07-14       Impact factor: 4.506

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.