| Literature DB >> 25924961 |
Dan-Dan Sun1, Xu Gu1, Jun-Guo Li1, Ting Yao1, Ying-Chao Dong1.
Abstract
The objective of this study was to evaluate the quality of five commercial enzyme linked immunosorbent assay (ELISA) kits (A, B, C, D, and E) from different suppliers for detecting aflatoxin B1 (AFB1). AFB1-free corn samples supplemented with different levels of AFB1 (5, 10, and 20 μg/kg) were used as positive controls and 6 replicates of each control sample were tested to evaluate the accuracy and precision of these kits. In addition, we also evaluated the performance of these ELISA kits for AFB1 in 30 feed samples, including corn, distillers dried grains with soluble, wheat samples, soybean meal, and poultry feed, which were verified by high performance liquid chromatography. Results showed that the coefficients of variation ranged from 1.18% to 16.22% in intra-plate and 2.85% to 18.04% in inter-plate for the determination of AFB1. The half maximal inhibitory concentration for five kits ranged from 3.72 to 7.22 μg/kg. The quantitation limits of AFB1 were all under the legal limit in China but somewhat inconsistent with kit instructions. Although the recovery rate of four of the five kits were either less than 90% or more than 110%, all these values were acceptable in practice. Two kits had high false positive rates (C and E). In conclusion, our results revealed that the qualities of five tested ELISA kits were significantly different.Entities:
Keywords: Aflatoxin B1; Enzyme Linked Immunosorbent Assay Kit; Evaluation; Feedstuffs
Year: 2015 PMID: 25924961 PMCID: PMC4413000 DOI: 10.5713/ajas.14.0868
Source DB: PubMed Journal: Asian-Australas J Anim Sci ISSN: 1011-2367 Impact factor: 2.509
CV of intra-plate and inter-plate for the five kits
| AFB1 spiking level (μg/kg) | CV (%) | |||||
|---|---|---|---|---|---|---|
|
| ||||||
| Kit A | Kit B | Kit C | Kit D | Kit E | ||
| Intra-plate | 5 | 8.93 | 9.85 | 16.22 | 9.05 | 10.95 |
| 10 | 10.02 | 8.35 | 5.99 | 1.18 | 7.40 | |
| 20 | 7.85 | 1.73 | 10.04 | 3.83 | 9.61 | |
| Inter-plate | 5 | 11.91 | 9.52 | 5.85 | 2.85 | 18.04 |
| 10 | 6.88 | 11.77 | 6.08 | 3.55 | 8.46 | |
| 20 | 6.95 | 6.96 | 4.19 | 7.83 | 4.48 | |
CV, coefficient of variation; AFB1, aflatoxin B1.
LOD, LOQ, and LOD marked in instructions (LODM) for five kits
| Kit A | Kit B | Kit C | Kit D | Kit E | |
|---|---|---|---|---|---|
| LOD (μg/kg) | 1.48 | 0.74 | 2.33 | 3.41 | 0.60 |
| LOQ (μg/kg) | 6.00 | 3.09 | 5.38 | 5.51 | 4.29 |
| LODM (μg/kg) | 1.25 | 1 | 3 | 5 | 2 |
LOD, limit of detection; LOQ, limit of quantification.
Average values of IC50 and CV for five kits
| Kit A | Kit B | Kit C | Kit D | Kit E | |
|---|---|---|---|---|---|
| IC50 (μg/kg) | 5.44 | 5.32 | 4.43 | 3.72 | 7.22 |
| CV (%) | 10.80 | 7.78 | 4.49 | 1.14 | 9.05 |
IC50, half maximal inhibitory concentration; CV, coefficient of variation.
Recovery rates for five kits
| Aflatoxin B1 spiking level (μg/kg) | Kit A | Kit B | Kit C | Kit D | Kit E |
|---|---|---|---|---|---|
| 5 | 85.50±11.65 | 111.05±14.23 | 78.21±13.36 | 146.18±10.27 | 52.67±15.81 |
| 10 | 93.92±10.04 | 128.02±16.86 | 86.86±6.68 | 132.69±5.43 | 53.89±5.58 |
| 20 | 92.91±8.70 | 97.64±4.97 | 90.57±9.19 | 101.09±7.12 | 57.11±6.45 |
Comparison of linear relationships for five kits
| Kit A | Kit B | Kit C | Kit D | Kit E | |
|---|---|---|---|---|---|
| Linear relationships | 0.9968 | 0.9983 | Curve fitting | 0.9843 | 0.9922 |
The abilities for five kits detecting aflatoxin B1 in feed samples
| Accurate number | False positive | False negative | |
|---|---|---|---|
| Kit A | 29 | 0 | 1 |
| Kit B | 25 | 4 | 1 |
| Kit C | 22 | 8 | 0 |
| Kit D | 28 | 1 | 1 |
| Kit E | 20 | 10 | 0 |