| Literature DB >> 2592306 |
Abstract
A gas chromatographic method for determination of vapor phase nicotine in environmental tobacco smoke (ETS) was collaboratively studied by 6 laboratories. Nicotine is desorbed from XAD-4 sample tubes with ethyl acetate containing triethylamine and determined by gas chromatography with nitrogen-selective detection. Each collaborator received blind duplicate samples at each of 6 nicotine concentrations. Three concentrations were generated by spiking XAD-4 tubes with known amounts of nicotine; the remaining 3 concentrations were ETS samples obtained in a carefully controlled environmental chamber containing sidestream and exhaled mainstream smoke from 1R4F Kentucky reference cigarettes. Repeatability and reproducibility relative standard deviations ranged from 4.4 to 11.1% and from 7.0 to 11.1%, respectively, for nicotine concentrations evaluated (up to 6 micrograms/cu m). The method has been adopted official first action.Entities:
Mesh:
Substances:
Year: 1989 PMID: 2592306
Source DB: PubMed Journal: J Assoc Off Anal Chem ISSN: 0004-5756