Literature DB >> 25922294

A dual mode breath sampler for the collection of the end-tidal and dead space fractions.

P Salvo1, C Ferrari2, R Persia1, S Ghimenti1, T Lomonaco1, F Bellagambi1, F Di Francesco3.   

Abstract

This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties.
Copyright © 2015. Published by Elsevier Ltd.

Entities:  

Keywords:  Breath analysis; Breath sampler; Dead space; End-tidal

Mesh:

Substances:

Year:  2015        PMID: 25922294     DOI: 10.1016/j.medengphy.2015.03.013

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Near-infrared tunable diode laser absorption spectroscopy-based determination of carbon dioxide in human exhaled breath.

Authors:  Cunguang Lou; Congrui Jing; Xin Wang; Yuhao Chen; Jiantao Zhang; Kaixuan Hou; Jianquan Yao; Xiuling Liu
Journal:  Biomed Opt Express       Date:  2019-10-02       Impact factor: 3.732

2.  Breath Analysis: Comparison among Methodological Approaches for Breath Sampling.

Authors:  Alessia Di Gilio; Jolanda Palmisani; Gianrocco Ventrella; Laura Facchini; Annamaria Catino; Niccolò Varesano; Pamela Pizzutilo; Domenico Galetta; Massimo Borelli; Pierluigi Barbieri; Sabina Licen; Gianluigi de Gennaro
Journal:  Molecules       Date:  2020-12-10       Impact factor: 4.411

3.  Inflammatory bowel disease and patterns of volatile organic compounds in the exhaled breath of children: A case-control study using Ion Molecule Reaction-Mass Spectrometry.

Authors:  Lorenzo Monasta; Chiara Pierobon; Andrea Princivalle; Stefano Martelossi; Annalisa Marcuzzi; Francesco Pasini; Luigi Perbellini
Journal:  PLoS One       Date:  2017-08-31       Impact factor: 3.240

Review 4.  Exhaled breath analysis: a review of 'breath-taking' methods for off-line analysis.

Authors:  Oluwasola Lawal; Waqar M Ahmed; Tamara M E Nijsen; Royston Goodacre; Stephen J Fowler
Journal:  Metabolomics       Date:  2017-08-19       Impact factor: 4.290

5.  A Linear-Quadratic Model for the Quantification of a Mixture of Two Diluted Gases with a Single Metal Oxide Sensor.

Authors:  Stéphanie Madrolle; Pierre Grangeat; Christian Jutten
Journal:  Sensors (Basel)       Date:  2018-06-01       Impact factor: 3.576

6.  Sport in Town: The Smart Healthy ENV Project, a Pilot Study of Physical Activity with Multiparametric Monitoring.

Authors:  Marco Laurino; Tommaso Lomonaco; Francesca Giuseppa Bellagambi; Silvia Ghimenti; Alessandro Messeri; Marco Morabito; Elena Marrucci; Lorenza Pratali; Maria Giovanna Trivella
Journal:  Int J Environ Res Public Health       Date:  2021-03-02       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.