Literature DB >> 25919982

An iridium oxide microelectrode for monitoring acute local pH changes of endothelial cells.

Shu Rui Ng1, Danny O'Hare.   

Abstract

pH sensors were fabricated by anodically electrodepositing iridium oxide films (AEIROFs) onto microelectrodes on chips and coated with poly(ethyleneimine) (PEI) for mechanical stability. These demonstrate super-Nernstian response to pH from pH 4.0 to 7.7 in chloride-free phosphate buffer. The surface of the chip was coated with fibronectin for the attachment of porcine aortic endothelial cells (PAECs). The working capability of the pH sensor for monitoring acute local pH changes was investigated by stimulating the PAECs with thrombin. Our results show that thrombin induced acute extracellular acidification of PAECs and dissolution of fibronectin, causing the local pH to decrease. The use of PD98059, a mitogen-activated protein kinase (MAPK) inhibitor, reduced extracellular acidification and an increase in local pH was observed. This study shows that our pH sensors can facilitate the investigation of acute cellular responses to stimulation by monitoring the real-time, local pH changes of cells attached to the sensors.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25919982     DOI: 10.1039/c5an00377f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Towards a minimally invasive device for beta-lactam monitoring in humans.

Authors:  Timothy Miles Rawson; Sanjiv Sharma; Pantelis Georgiou; Alison Holmes; Anthony Cass; Danny O'Hare
Journal:  Electrochem commun       Date:  2017-09       Impact factor: 4.724

2.  Concept and Development of an Electronic Framework Intended for Electrode and Surrounding Environment Characterization In Vivo.

Authors:  Stefan B Rieger; Jennifer Pfau; Thomas Stieglitz; Maria Asplund; Juan S Ordonez
Journal:  Sensors (Basel)       Date:  2016-12-30       Impact factor: 3.576

Review 3.  Closed-Loop Implantable Therapeutic Neuromodulation Systems Based on Neurochemical Monitoring.

Authors:  Khalid B Mirza; Caroline T Golden; Konstantin Nikolic; Christofer Toumazou
Journal:  Front Neurosci       Date:  2019-08-20       Impact factor: 4.677

4.  Micropatterning of planar metal electrodes by vacuum filling microfluidic channel geometries.

Authors:  Stelios Chatzimichail; Pashiini Supramaniam; Oscar Ces; Ali Salehi-Reyhani
Journal:  Sci Rep       Date:  2018-09-26       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.