Epipolar Consistency in Transmission Imaging.

André Aichert, Martin Berger, Jian Wang, Nicole Maass, Arnd Doerfler, Joachim Hornegger, Andreas K Maier.   

Abstract

This paper presents the derivation of the Epipolar Consistency Conditions (ECC) between two X-ray images from the Beer-Lambert law of X-ray attenuation and the Epipolar Geometry of two pinhole cameras, using Grangeat's theorem. We motivate the use of Oriented Projective Geometry to express redundant line integrals in projection images and define a consistency metric, which can be used, for instance, to estimate patient motion directly from a set of X-ray images. We describe in detail the mathematical tools to implement an algorithm to compute the Epipolar Consistency Metric and investigate its properties with detailed random studies on both artificial and real FD-CT data. A set of six reference projections of the CT scan of a fish were used to evaluate accuracy and precision of compensating for random disturbances of the ground truth projection matrix using an optimization of the consistency metric. In addition, we use three X-ray images of a pumpkin to prove applicability to real data. We conclude, that the metric might have potential in applications related to the estimation of projection geometry. By expression of redundancy between two arbitrary projection views, we in fact support any device or acquisition trajectory which uses a cone-beam geometry. We discuss certain geometric situations, where the ECC provide the ability to correct 3D motion, without the need for 3D reconstruction.

Entities:  

Mesh:

Year:  2015        PMID: 25915956     DOI: 10.1109/TMI.2015.2426417

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Symmetry prior for epipolar consistency.

Authors:  Alexander Preuhs; Andreas Maier; Michael Manhart; Markus Kowarschik; Elisabeth Hoppe; Javad Fotouhi; Nassir Navab; Mathias Unberath
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-12       Impact factor: 2.924

2.  Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

Authors:  M Berger; K Müller; A Aichert; M Unberath; J Thies; J-H Choi; R Fahrig; A Maier
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

3.  Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging.

Authors:  Bernhard Stimpel; Christopher Syben; Tobias Würfl; Katharina Breininger; Philip Hoelter; Arnd Dörfler; Andreas Maier
Journal:  Sci Rep       Date:  2019-12-11       Impact factor: 4.379