Capacity of dental equipment to interfere with cardiac implantable electrical devices.

Eduard Lahor-Soler1, Jaume Miranda-Rius, Lluís Brunet-Llobet, Xavier Sabaté de la Cruz.   

Abstract

Patients with cardiac implantable electrical devices should take precautions when exposed to electromagnetic fields. Possible interference as a result of proximity to electromagnets or electricity flow from electronic tools employed in clinical odontology remains controversial. The objective of this study was to examine in vitro the capacity of dental equipment to provoke electromagnetic interference in pacemakers and implantable cardioverter defibrillators. Six electronic dental instruments were tested on three implantable cardioverter defibrillators and three pacemakers from different manufacturers. A simulator model, submerged in physiological saline, with elements that reproduced life-size anatomic structures was used. The instruments were analyzed at differing distances and for different time periods of application. The dental instruments studied displayed significant differences in their capacity to trigger electromagnetic interference. Significant differences in the quantity of registered interference were observed with respect to the variables manufacturer, type of cardiac implant, and application distance but not with the variable time of application. The electronic dental equipment tested at a clinical application distance (20 cm) provoked only slight interference in the pacemakers and implantable cardioverter defibrillators employed, irrespective of manufacturer.
© 2015 Eur J Oral Sci.

Entities:  

Keywords:  cardiac implantable electrical devices; dental surgical equipment; electromagnetic interference; implantable cardioverter defibrillator; pacemaker

Mesh:

Year:  2015        PMID: 25913780     DOI: 10.1111/eos.12183

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  2 in total

1.  Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic devices: a systematic review.

Authors:  Mothanna K AlRahabi; Hani M Ghabbani
Journal:  Libyan J Med       Date:  2019-12       Impact factor: 1.657

2.  Electromagnetic interference in cardiac electronic implants caused by novel electrical appliances emitting electromagnetic fields in the intermediate frequency range: a systematic review.

Authors:  Sarah Driessen; Andreas Napp; Kristina Schmiedchen; Thomas Kraus; Dominik Stunder
Journal:  Europace       Date:  2019-02-01       Impact factor: 5.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.