Literature DB >> 25911884

High intensity focused ultrasound ablation for patients with inoperable liver cancer.

Lianyu Chen, Kun Wang, Zhen Chen, Zhiqiang Meng, Hao Chen, Huifeng Gao, Peng Wang, Huili Zhu, Junhua Lin, Luming Liu.   

Abstract

BACKGROUND/AIMS: To analyses the feasibility and efficacy of high intensity focused ultrasound (HIFU) treatment in patients with inoperable liver cancer.
METHODOLOGY: 187 patients were treated with HIFU, of all these patients 116 cases were Primary Liver Cancer (PLC) and 71 cases were Metastatic Liver Cancer (MLC). According to some parameters, such as clinical symptoms, the basis of main organs functional tests, imaging examinations, and progression-free survival (PFS) time to assess the safety and efficacy of HIFU in the treatment of liver cancer.
RESULTS: 55 patients (29.4%) achieved CR and 73 patients (39.0%) achieved PR, 32 patients (17.1%) had responses of SD, and 27 patients (14.4%) were PD, respectively. Response rates were 90.5% (32 CR + 6 PR/42) in left lobe cancer and 64.1% (22 CR + 62 PR/131) in right lobe cancer. The median PFS for those CR case was 7 months, of PLC was 8 months, of MLC was 5 months.
CONCLUSIONS: HIFU is effective and feasible in the treatment of liver cancer. It offer a significant noninvasive therapy for local treatment of liver cancer. For those right lobe liver cancers or with poor ultrasonic window, increasing treatment time or repeated treatment may improve the efficiency of HIFU ablation.

Entities:  

Mesh:

Year:  2015        PMID: 25911884

Source DB:  PubMed          Journal:  Hepatogastroenterology        ISSN: 0172-6390


  4 in total

1.  Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods.

Authors:  John Civale; Ian Rivens; Adam Shaw; Gail Ter Haar
Journal:  Phys Med Biol       Date:  2018-03-07       Impact factor: 3.609

Review 2.  Clinical Application of High-intensity Focused Ultrasound in Cancer Therapy.

Authors:  Yi-Hsuan Hsiao; Shou-Jen Kuo; Horng-Der Tsai; Ming-Chih Chou; Guang-Perng Yeh
Journal:  J Cancer       Date:  2016-01-03       Impact factor: 4.207

3.  Deep tissue penetration of nanoparticles using pulsed-high intensity focused ultrasound.

Authors:  Dong Gil You; Hong Yeol Yoon; Sangmin Jeon; Wooram Um; Sejin Son; Jae Hyung Park; Ick Chan Kwon; Kwangmeyung Kim
Journal:  Nano Converg       Date:  2017-11-08

4.  High-Intensity Focused Ultrasound Ablation for Unresectable Primary and Metastatic Liver Cancer: Real-World Research in a Chinese Tertiary Center With 275 Cases.

Authors:  Yongshuo Ji; Junqiu Zhu; Linglin Zhu; Yanfei Zhu; Hong Zhao
Journal:  Front Oncol       Date:  2020-10-29       Impact factor: 6.244

  4 in total