Literature DB >> 25911250

Hemodynamic insight into overlapping bare-metal stents strategy in the treatment of aortic aneurysm.

Peng Zhang1, Xiao Liu2, Anqiang Sun1, Yubo Fan1, Xiaoyan Deng3.   

Abstract

Clinical trials have shown overlapping bare-metal stents provoke effective thrombus clot within the aneurysm sac and shrinkage of the aneurysm by directly regulating the hemodynamics. To gain insight into the hemodynamic mechanism of the technique, three cases of simplified thoracic aortic aneurysm models (with no stent, a single stent and two overlapped stents deployed within the aneurysm sac) were studied and compared in terms of time-varying velocity and shear rate, time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and relative residence time (RRT). The results demonstrated that the overlapping stents' strategy was more effective in reducing the velocity of blood flow within the aneurysm, especially for the area near the aneurysm wall. Stenting induced a dramatic change trend of shear rate during the cardiac cycle, in which a very high shear rate (>10,000 s(-1)) during the systole and a quite low shear rate (<1000 s(-1)) during the diastole were observed, respectively. Moreover, reduced TAWSS and OSI and elevated RRT values were observed on the aneurysm wall after stent placement. The effects of stenting on the shear rate, TAWSS, OSI and RRT in the aneurysm would be significantly enhanced by two overlapped stents. The present findings therefore indicated that, the overlapping bare-metal stents can isolate the aneurysm effectively and may create a favorable hemodynamic environment provoking platelets activation and aggregation within the aneurysm, which may promote thrombus formation/growth there, hence contribute to degradation of the aneurysm.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hemodynamics; Overlapping bare-metal stents; Shear rate; Thoracic aortic aneurysm; Thrombus; Wall shear stress

Mesh:

Substances:

Year:  2015        PMID: 25911250     DOI: 10.1016/j.jbiomech.2015.03.028

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Reduced Activity of von Willebrand Factor after Flow-Diverting Stent Implantation for Intracranial Aneurysms: A Link to Acquired von Willebrand Disease?

Authors:  I Oran; C Cinar; H Bozkaya; M Parildar; S Duman
Journal:  AJNR Am J Neuroradiol       Date:  2020-01-02       Impact factor: 3.825

2.  Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm.

Authors:  Siang Lin Yeow; Hwa Liang Leo
Journal:  Comput Math Methods Med       Date:  2016-05-09       Impact factor: 2.238

3.  Hemodynamics study of a multilayer stent for the treatment of aneurysms.

Authors:  Yan Xiong; Xuhong Wang; Wentao Jiang; Xiaobao Tian; Qingyuan Wang; Yubo Fan; Yu Chen
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

4.  Numerical and Experimental Investigation of the Hemodynamic Performance of Bifurcated Stent Grafts with Various Torsion Angles.

Authors:  Ming Liu; Anqiang Sun; Xiaoyan Deng
Journal:  Sci Rep       Date:  2018-08-22       Impact factor: 4.379

5.  Hemodynamic Performance of Multilayer Stents in the Treatment of Aneurysms with a Branch Attached.

Authors:  Zhongyou Li; Lijuan Hu; Chong Chen; Zhenze Wang; Zhihong Zhou; Yu Chen
Journal:  Sci Rep       Date:  2019-07-15       Impact factor: 4.379

6.  Multilayer bare stent technique in treating intact mycotic suprarenal aortic aneurysm: a case report.

Authors:  Chao Song; Qing Cai; Yi Huang; Qingsheng Lu
Journal:  Eur Heart J Case Rep       Date:  2020-11-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.