Literature DB >> 25911117

Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm.

A D Annoni1, D Andreini2, G Pontone3, A Formenti3, M Petullà3, E Consiglio3, E Nobili3, A Baggiano3, E Conte3, S Mushtaq3, E Bertella3, F Billi3, A L Bartorelli2, P Montorsi2, M Pepi3.   

Abstract

AIMS: To evaluate the feasibility of ultra-low-dose CT for left atrium and pulmonary veins using new model-based iterative reconstruction (MBIR) algorithm. METHODS AND
RESULTS: Two hundred patients scheduled for catheter ablation were randomized into two groups: Group 1 (100 patients, Multidetector row CT (MDCT) with MBIR, no ECG triggering, tube voltage and tube current of 100 kV and 60 mA, respectively) and Group 2 [100 patients, MDCT with adaptive statistical iterative reconstruction algorithm (ASIR), no ECG triggering, and kV and mA tailored on patient BMI]. Image quality, CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of left atrium (LA) and pulmonary veins, and effective dose (ED) were evaluated for each exam and compared between two groups.No significant differences between groups in terms of population characteristics, cardiovascular risk factors, anatomical features, prevalence of persistent atrial fibrillation and image quality score. Statistically significant differences were found between Group 1 and Group 2 in mean attenuation, SNR, and CNR of LA. Significantly, lower values of noise were found in Group 1 versus Group 2. Group 1 showed a significantly lower mean ED in comparison with Group 2 (0.41 ± 0.04 versus 4.17 ± 2.7 mSv).
CONCLUSION: The CT for LA and pulmonary veins imaging using MBIR is feasible and allows examinations with very low-radiation exposure without loss of image quality. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  atrial fibrillation; computed tomography imaging; dose-reducing software; left atrium

Mesh:

Substances:

Year:  2015        PMID: 25911117     DOI: 10.1093/ehjci/jev103

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  10 in total

1.  Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study.

Authors:  Akinori Hata; Masahiro Yanagawa; Osamu Honda; Tomoko Gyobu; Ken Ueda; Noriyuki Tomiyama
Journal:  Eur Radiol       Date:  2016-03-17       Impact factor: 5.315

2.  Assessment of noise reduction potential and image quality improvement of a new generation adaptive statistical iterative reconstruction (ASIR-V) in chest CT.

Authors:  Hui Tang; Nan Yu; Yongjun Jia; Yong Yu; Haifeng Duan; Dong Han; Guangming Ma; Chenglong Ren; Taiping He
Journal:  Br J Radiol       Date:  2017-11-16       Impact factor: 3.039

Review 3.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

4.  Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT.

Authors:  Heloise Barras; Vincent Dunet; Anne-Lise Hachulla; Jochen Grimm; Catherine Beigelman-Aubry
Journal:  Acta Radiol Open       Date:  2016-08-24

5.  X-Ray Exposure in Cardiac Electrophysiology: A Retrospective Analysis in 8150 Patients Over 7 Years of Activity in a Modern, Large-Volume Laboratory.

Authors:  Michela Casella; Antonio Dello Russo; Eleonora Russo; Valentina Catto; Francesca Pizzamiglio; Martina Zucchetti; Benedetta Majocchi; Stefania Riva; Giulia Vettor; Maria Antonietta Dessanai; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Carlo Vignati; Sergio Conti; Alice Bonomi; Corrado Carbucicchio; Luigi Di Biase; Andrea Natale; Claudio Tondo
Journal:  J Am Heart Assoc       Date:  2018-05-22       Impact factor: 5.501

6.  OPTimal IMAging strategy in patients suspected of non-traumatic pulmonary disease at the emergency department: chest X-ray or ultra-low-dose CT (OPTIMACT)-a randomised controlled trial chest X-ray or ultra-low-dose CT at the ED: design and rationale.

Authors:  Inge A H van den Berk; Maadrika M N P Kanglie; Tjitske S R van Engelen; Shandra Bipat; Marcel G W Dijkgraaf; Patrick M M Bossuyt; Wouter de Monyé; Jan M Prins; Jaap Stoker
Journal:  Diagn Progn Res       Date:  2018-08-08

7.  Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp.

Authors:  Chankue Park; Ki Seok Choo; Jin Hyeok Kim; Kyung Jin Nam; Ji Won Lee; Jin You Kim
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

8.  Ultra-low-dose chest computed tomography for interstitial lung disease using model-based iterative reconstruction with or without the lung setting.

Authors:  Akinori Hata; Masahiro Yanagawa; Osamu Honda; Tomo Miyata; Noriyuki Tomiyama
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

9.  Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation: A comparison of 2 versus 4 frame rate.

Authors:  Ji Hyun Lee; Jun Kim; Minsu Kim; Jongmin Hwang; You Mi Hwang; Joon-Won Kang; Gi-Byoung Nam; Kee-Joon Choi; You-Ho Kim
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.817

10.  Reduced Radiation Exposure Protocol during Computer Tomography of the Left Atrium Prior to Catheter Ablation in Patients with Atrial Fibrillation.

Authors:  Tomasz Jadczyk; Jiri Wolf; Martin Pesl; Filip Soucek; Frantisek Lehar; Jiri Jez; Tomas Kulik; Bohdan Tyshchenko; Silvie Belaskova; Petr Ourednicek; Guido Caluori; Miroslav Novak; Zdenek Starek
Journal:  Diagnostics (Basel)       Date:  2022-03-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.