Literature DB >> 25907050

Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging.

André T Stevenson1, Laura M Reese2, Tanner K Hill3, Jeffrey McGuire4, Aaron M Mohs3, Raj Shekhar5, Lissett R Bickford6, Abby R Whittington7.   

Abstract

Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35 ± 5.08% dye leached out of catheters. The addition of 0.025 wt% dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1 cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Catheter; Cell adhesion; Fluorescence; Mechanical testing; Polyurethane

Mesh:

Substances:

Year:  2015        PMID: 25907050      PMCID: PMC4417621          DOI: 10.1016/j.biomaterials.2015.03.020

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  17 in total

1.  A clearer vision for in vivo imaging.

Authors:  R Weissleder
Journal:  Nat Biotechnol       Date:  2001-04       Impact factor: 54.908

2.  Platelet adhesion and human umbilical vein endothelial cell cytocompatibility of biodegradable segmented polyurethanes prepared with 4,4'-methylene bis(cyclohexyl isocyanate), poly(caprolactone) diol and butanediol or dithioerythritol as chain extenders.

Authors:  L H Chan-Chan; R F Vargas-Coronado; J M Cervantes-Uc; J V Cauich-Rodríguez; R Rath; E A Phelps; A J García; J San Román Del Barrio; J Parra; Y Merhi; M Tabrizian
Journal:  J Biomater Appl       Date:  2012-06-07       Impact factor: 2.646

3.  Repositioning techniques for malpositioned neonatal peripherally inserted central catheters.

Authors:  Elizabeth L Sharpe
Journal:  Adv Neonatal Care       Date:  2010-06       Impact factor: 1.968

4.  Bedside ultrasound can safely eliminate the need for chest radiographs after central venous catheter placement: CVC sono in the surgical ICU (SICU).

Authors:  Kazuhide Matsushima; Heidi L Frankel
Journal:  J Surg Res       Date:  2010-05-11       Impact factor: 2.192

5.  Is chest X-ray still necessary after central venous catheter insertion?

Authors:  Christine Ammirati; Julien Maizel; Michel Slama
Journal:  Crit Care Med       Date:  2010-02       Impact factor: 7.598

6.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

Review 7.  Videos in clinical medicine. PICC placement in the neonate.

Authors:  Amy S McCay; Elizabeth C Elliott; Marlene Walden
Journal:  N Engl J Med       Date:  2014-03-13       Impact factor: 91.245

8.  Membrane type I-matrix metalloproteinase-mediated degradation of type I collagen by oral squamous cell carcinoma cells.

Authors:  S Aznavoorian; B A Moore; L D Alexander-Lister; S L Hallit; L J Windsor; J A Engler
Journal:  Cancer Res       Date:  2001-08-15       Impact factor: 12.701

Review 9.  Radiation biology for pediatric radiologists.

Authors:  Eric J Hall
Journal:  Pediatr Radiol       Date:  2008-12-16

10.  Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: an alternative to chest radiography.

Authors:  Antonella Vezzani; Claudia Brusasco; Salvatore Palermo; Claudio Launo; Mario Mergoni; Francesco Corradi
Journal:  Crit Care Med       Date:  2010-02       Impact factor: 7.598

View more
  1 in total

1.  Physically Targeted Intravenous Polyurethane Nanoparticles for Controlled Release of Atorvastatin Calcium

Authors:  Behnaz Sadat Eftekhari; Akbar Karkhaneh; Ali Alizadeh
Journal:  Iran Biomed J       Date:  2017-05-23
  1 in total