Literature DB >> 25902942

Screen-printed back-to-back electroanalytical sensors: heavy metal ion sensing.

Ana P Ruas de Souza1, Christopher W Foster, Athanasios V Kolliopoulos, Mauro Bertotti, Craig E Banks.   

Abstract

Screen-printed back-to-back microband electroanalytical sensors are applied to the quantification of lead(II) ions for the first time. In this configuration the electrodes are positioned back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor. Proof-of-concept is demonstrated for the electroanalytical sensing of lead(II) ions utilising square-wave anodic stripping voltammetry where an increase in the electroanalytical sensitivity is observed by a factor of 5 with the back-to-back microband configuration at a fixed lead(II) ion concentration of 5 μg L(-1) utilising a deposition potential and time of -1.2 V and 30 seconds respectively, compared to a conventional (single) microband electrode. The back-to-back microband configuration allows for the sensing of lead(II) ions with a linear range from 5 to 110 μg L(-1) with a limit of detection (based on 3σ) corresponding to 3.7 μg L(-1). The back-to-back microband configuration is demonstrated to quantify the levels of lead(II) ions within drinking water corresponding to a level of 2.8 (±0.3) μg L(-1). Independent validation was performed using ICP-OES with the levels of lead(II) ions found to correspond to 2.5 (±0.1) μg L(-1); the excellent agreement between the two methods validates the electroanalytical procedure for the quantification of lead(II) ions in drinking water. This back-to-back configuration exhibits an excellent validated analytical performance for the determination of lead(II) ions within drinking water at World Health Organisation levels (limited to 10 μg L(-1) within drinking water).

Entities:  

Year:  2015        PMID: 25902942     DOI: 10.1039/c5an00381d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  The Graphene/l-Cysteine/Gold-Modified Electrode for the Differential Pulse Stripping Voltammetry Detection of Trace Levels of Cadmium.

Authors:  Yu Song; Chao Bian; Jianhua Tong; Yang Li; Shanghong Xia
Journal:  Micromachines (Basel)       Date:  2016-06-13       Impact factor: 2.891

2.  Detection Efficiency of Ag Nanoparticle Labels for a Heart Failure Marker Using Linear and Square-Wave Anodic Stripping Voltammetry.

Authors:  Nikhil Raj; Richard M Crooks
Journal:  Biosensors (Basel)       Date:  2022-03-29
  2 in total