B-K Tran1, C P Herbort1. 1. Inflammatory and Retinal Eye Diseases, Centre for Ophthalmic Specialised Care, Lausanne, Switzerland.
Abstract
BACKGROUND: Best corrected visual acuity (BCVA) of 0.8 or above in AMD patients can sometimes correspond to poor macular function inducing a serious visual handicap. Microperimetry can be used to objectivize this difference. PATIENTS AND METHODS: A retrospective study was undertaken on 233 files of AMD patients of whom 82 had had a microperimetry. BCVA was compared with microperimetry performance. All examinations were performed in an identical setting by the same team of 3 persons. RESULTS: Among the 82 patients included, 32 (39.0%) had a BCVA equal to or above 0.8 even though their microperimetry performance was lower than 200/560 db. 10 of them (12.2% of total) had an even poorer microperimetry below 120/560 db indicating poor macular function. CONCLUSIONS: More than a third of the AMD patients had a bad or very bad microperimetry performance in parallel with a good visual acuity. Microperimetry is a valuable tool to assess and follow real macular function in AMD patients when visual acuity alone can be misleading. Georg Thieme Verlag KG Stuttgart · New York.
BACKGROUND: Best corrected visual acuity (BCVA) of 0.8 or above in AMDpatients can sometimes correspond to poor macular function inducing a serious visual handicap. Microperimetry can be used to objectivize this difference. PATIENTS AND METHODS: A retrospective study was undertaken on 233 files of AMDpatients of whom 82 had had a microperimetry. BCVA was compared with microperimetry performance. All examinations were performed in an identical setting by the same team of 3 persons. RESULTS: Among the 82 patients included, 32 (39.0%) had a BCVA equal to or above 0.8 even though their microperimetry performance was lower than 200/560 db. 10 of them (12.2% of total) had an even poorer microperimetry below 120/560 db indicating poor macular function. CONCLUSIONS: More than a third of the AMDpatients had a bad or very bad microperimetry performance in parallel with a good visual acuity. Microperimetry is a valuable tool to assess and follow real macular function in AMDpatients when visual acuity alone can be misleading. Georg Thieme Verlag KG Stuttgart · New York.
Authors: Katarzyna Michalska-Małecka; Jakub Kałużny; Mariusz Nowak; Poitr Gościniewicz; Anna Matysik-Woźniak; Katarzyna Nowomiejska; Jacek Karpe; Robert Rejdak Journal: Medicine (Baltimore) Date: 2019-11 Impact factor: 1.817
Authors: Susanne G Pondorfer; Manuel Heinemann; Maximilian W M Wintergerst; Maximilian Pfau; Annika L Strömer; Frank G Holz; Robert P Finger Journal: PLoS One Date: 2020-04-16 Impact factor: 3.240
Authors: Susanne G Pondorfer; Jan H Terheyden; Manuel Heinemann; Maximilian W M Wintergerst; Frank G Holz; Robert P Finger Journal: Sci Rep Date: 2019-10-25 Impact factor: 4.379