Literature DB >> 25902099

Measurement of Optic Nerve Sheath Diameter: Differences between Methods? A Pilot Study.

C Giger-Tobler1, J Eisenack1, D Holzmann2, A Pangalu3, V Sturm4, H E Killer5, K Landau1, G P Jaggi1.   

Abstract

BACKGROUND: Quantification of the optic nerve sheath diameter is a promising approach for the detection of elevated intracranial pressure. The comparability of current methods is unclear. The objective of this study was to assess the relationship between optic nerve sheath diameter as measured with computed tomography, magnetic resonance tomography and ultrasound in patients without known optic nerve disease or increased intracranial pressure. PATIENTS AND METHODS: 15 patients (60.8 [years]±16.73 SD; 7 female) with paranasal sinus pathology in whom computed tomography and magnetic resonance imaging were performed underwent optic nerve sheath diameter measurements by ultrasound, as well as an ophthalmological examination. Ultrasound-, computed tomography- and magnetic resonance imaging-derived maximal optic nerve sheath diameter values 3 mm behind the globe were compared.
RESULTS: Optic nerve sheath diameter measured (n=30) by ultrasound (mean 6.2 [mm]±0.84 SD) was significantly (p<0.01) higher than optic nerve sheath diameter in computed tomography (5.2±1.11) or magnetic resonance imaging (5.3±1.14). There was no significant (p=0.24) difference between optic nerve sheath diameter measured in computed tomography and magnetic resonance tomography.
CONCLUSIONS: The comparability of optic nerve sheath diameter measurements in patients without known optic nerve disease and assumed normal intracranial pressure appears to be given between computed tomography and magnetic resonance tomography, while comparability between ultrasound and computed tomography or magnetic resonance tomography seems to be less reliable. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2015        PMID: 25902099     DOI: 10.1055/s-0035-1545711

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  2 in total

1.  Diagnostic value of neuro-ophthalmological signs in cases of Chiari I malformation.

Authors:  Inessa Bekerman; Tal Sigal; Itzhak Kimiagar; Zina Evy Almer; Michael Vaiman
Journal:  Childs Nerv Syst       Date:  2016-11-08       Impact factor: 1.475

2.  Optic Nerve Measurement on MRI in the Pediatric Population: Normative Values and Correlations.

Authors:  C E Al-Haddad; M G Sebaaly; R N Tutunji; C J Mehanna; S R Saaybi; A M Khamis; R G Hourani
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-07       Impact factor: 3.825