Literature DB >> 25899650

Diagnostic performance of focused cardiac ultrasound performed by emergency physicians for the assessment of ascending aorta dilation and aneurysm.

Peiman Nazerian1, Simone Vanni1, Fulvio Morello2, Matteo Castelli1, Maddalena Ottaviani1, Claudia Casula1, Alessandra Petrioli1, Maurizio Bartolucci3, Stefano Grifoni1.   

Abstract

OBJECTIVES: The diagnostic performance of transthoracic focused cardiac ultrasound (FoCUS) performed by emergency physicians (EP) to estimate ascending aorta dimensions in the acute setting has not been prospectively studied. The diagnostic accuracy and the interobserver variability of EP-performed FoCUS were investigated to estimate thoracic aortic dilation and aneurysm compared with the results of computed tomography angiography (CTA).
METHODS: This was a prospective single-center cohort study of a convenience sample of patients who underwent CTA in the emergency department for suspected aortic pathology. FoCUS was performed before CTA, and the maximum ascending aorta diameter evaluated in parasternal long-axis view. Aorta diameter < 40 mm by visual estimation or by diameter measurement was considered normal. Measurements were recorded in all patients with aorta diameter ≥ 40 mm. Diagnostic accuracy of FoCUS for detection of aortic dilation (diameter ≥ 40 mm) and aneurysm (diameter ≥ 45 mm) were calculated considering the CTA result as reference standard. In a subgroup of patients, a second EP-sonographer performed FoCUS to evaluate interobserver agreement for the diagnosis of ascending aorta dilation.
RESULTS: A total of 140 patients were enrolled in the study. Ascending aorta dilation and aneurysm were detected with FoCUS in 50 (35.7%) and in 27 (17.8%) patients, respectively. Sensitivity and specificity of FoCUS were 78.6% (95% confidence interval [CI] = 65.6% to 88.4%) and 92.9% (95% CI = 85.1% to 97.3%), respectively, for ascending aorta dilation and 64.7% (95% CI = 46.5% to 80.2%) and 95.3% (95% CI = 89.3% to 98.4%), respectively, for ascending aorta aneurysm. Interobserver agreement of FoCUS was k = 0.82.
CONCLUSIONS: FoCUS performed by EP is specific for ascending aorta dilation and aneurysm when compared to CTA and appears a reproducible technique.
© 2015 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2015        PMID: 25899650     DOI: 10.1111/acem.12650

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  2 in total

1.  Evaluation of diagnostic efficiency of bedside cardiac ultrasonography performed by emergency specialist.

Authors:  Ibrahim Halil Toksul; Mustafa Kesapli; Akkan Avci; Ramazan Guven
Journal:  Ir J Med Sci       Date:  2022-08-12       Impact factor: 2.089

2.  Acute ischemic stroke what is hidden behind?

Authors:  Joaquín Valle Alonso; David Martin; Harriet Kinderman; Islam Farhad; Peter Swallow; Aidan Siggers
Journal:  J Cardiol Cases       Date:  2017-08-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.