Literature DB >> 25892692

Microfiltration: Effect of channel diameter on limiting flux and serum protein removal.

E E Hurt1, M C Adams1, D M Barbano2.   

Abstract

Our objective was to determine the limiting flux and serum protein (SP) removal at 8, 9 and 10% true protein (TP) in the retentate recirculation loop using 0.1-µm ceramic graded permeability (GP) microfiltration (MF) membranes with 3mm channel diameters (CD). An additional objective was to compare the limiting flux and SP removal between 0.1-µm ceramic GP membranes with 3mm CD and previous research using 4-mm CD membranes. The MF system was operated at 50°C, using a diluted milk protein concentrate with 85% protein on a total solids basis (MPC85) as the MF feed. The limiting flux for the MF of diluted MPC85 was determined at 8, 9, and 10% TP concentration in the recirculation loop. The experiment using the 3-mm CD membranes was replicated 3 times for a total of 9 runs. On the morning of each run MPC85 was diluted with reverse osmosis water to a MF feed TP concentration of 5.4%. In all runs the starting flux was 55 kg/m2 per hour, the flux was then increased in steps until the limiting flux was reached. For the 3-mm CD membranes, the limiting flux was 128±0.3, 109±4, and 97±0.5 kg/m2 per hour at recirculation loop TP concentrations of 8.1±0.07, 9.2±0.04, and 10.2±0.03%, respectively. For the 3-mm CD membranes, increasing the flux from the starting to the limiting flux decreased the SP removal factor from 0.72±0.02 to 0.67±0.01; however, no difference in SP removal factor among the target recirculation loop TP concentrations was detected. The limiting flux at each recirculation loop target TP concentration was lower for the 3- compared with the 4-mm CD membranes. The differences in limiting fluxes between the 3- and 4-mm CD membranes were explained in part by the difference in cross-flow velocity (5.5±0.03 and 7.0±0.03 m/s for the 3- and 4-mm CD membranes, respectively). The SP removal factor was also lower for the 3- compared with the 4-mm CD membranes, indicating that more membrane fouling may have occurred in the 3- versus 4-mm CD membranes.
Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  limiting flux; microfiltration; serum protein removal

Mesh:

Substances:

Year:  2015        PMID: 25892692     DOI: 10.3168/jds.2014-9225

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  1 in total

1.  Prediction of the Limiting Flux and Its Correlation with the Reynolds Number during the Microfiltration of Skim Milk Using an Improved Model.

Authors:  Carolina Astudillo-Castro; Andrés Cordova; Vinka Oyanedel-Craver; Carmen Soto-Maldonado; Pedro Valencia; Paola Henriquez; Rafael Jimenez-Flores
Journal:  Foods       Date:  2020-11-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.