Literature DB >> 25892634

Artificial neural network modelling of pharmaceutical residue retention times in wastewater extracts using gradient liquid chromatography-high resolution mass spectrometry data.

Kelly Munro1, Thomas H Miller1, Claudia P B Martins2, Anthony M Edge3, David A Cowan1, Leon P Barron4.   

Abstract

The modelling and prediction of reversed-phase chromatographic retention time (tR) under gradient elution conditions for 166 pharmaceuticals in wastewater extracts is presented using artificial neural networks for the first time. Radial basis function, multilayer perceptron and generalised regression neural networks were investigated and a comparison of their predictive ability for model solutions discussed. For real world application, the effect of matrix complexity on tR measurements is presented. Measured tR for some compounds in influent wastewater varied by >1min in comparison to tR in model solutions. Similarly, matrix impact on artificial neural network predictive ability was addressed towards developing a more robust approach for routine screening applications. Overall, the best neural network had a predictive accuracy of <1.3min at the 75th percentile of all measured tR data in wastewater samples (<10% of the total runtime). Coefficients of determination for 30 blind test compounds in wastewater matrices lay at or above R(2)=0.92. Finally, the model was evaluated for application to the semi-targeted identification of pharmaceutical residues during a weeklong wastewater sampling campaign. The model successfully identified native compounds at a rate of 83±4% and 73±5% in influent and effluent extracts, respectively. The use of an HRMS database and the optimised ANN model was also applied to shortlisting of 37 additional compounds in wastewater. Ultimately, this research will potentially enable faster identification of emerging contaminants in the environment through more efficient post-acquisition data mining.
Copyright © 2015 Elsevier B.V. All rights reserved.

Keywords:  Artificial neural networks; High resolution mass spectrometry; Retention time prediction; Reversed-phase liquid chromatography; Semi-targeted detection

Mesh:

Substances:

Year:  2015        PMID: 25892634     DOI: 10.1016/j.chroma.2015.03.063

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  9 in total

1.  A comparison of three liquid chromatography (LC) retention time prediction models.

Authors:  Andrew D McEachran; Kamel Mansouri; Seth R Newton; Brandiese E J Beverly; Jon R Sobus; Antony J Williams
Journal:  Talanta       Date:  2018-01-11       Impact factor: 6.057

2.  Uptake, biotransformation and elimination of selected pharmaceuticals in a freshwater invertebrate measured using liquid chromatography tandem mass spectrometry.

Authors:  Thomas H Miller; Nicolas R Bury; Stewart F Owen; Leon P Barron
Journal:  Chemosphere       Date:  2017-05-13       Impact factor: 7.086

3.  The First Attempt at Non-Linear in Silico Prediction of Sampling Rates for Polar Organic Chemical Integrative Samplers (POCIS).

Authors:  Thomas H Miller; Jose A Baz-Lomba; Christopher Harman; Malcolm J Reid; Stewart F Owen; Nicolas R Bury; Kevin V Thomas; Leon P Barron
Journal:  Environ Sci Technol       Date:  2016-07-18       Impact factor: 9.028

Review 4.  A review of the pharmaceutical exposome in aquatic fauna.

Authors:  Thomas H Miller; Nicolas R Bury; Stewart F Owen; James I MacRae; Leon P Barron
Journal:  Environ Pollut       Date:  2018-04-10       Impact factor: 8.071

Review 5.  Strategies for structure elucidation of small molecules based on LC-MS/MS data from complex biological samples.

Authors:  Zhitao Tian; Fangzhou Liu; Dongqin Li; Alisdair R Fernie; Wei Chen
Journal:  Comput Struct Biotechnol J       Date:  2022-09-07       Impact factor: 6.155

Review 6.  Insight into chemical basis of traditional Chinese medicine based on the state-of-the-art techniques of liquid chromatography-mass spectrometry.

Authors:  Yang Yu; Changliang Yao; De-An Guo
Journal:  Acta Pharm Sin B       Date:  2021-02-26       Impact factor: 11.413

7.  High-throughput multi-residue quantification of contaminants of emerging concern in wastewaters enabled using direct injection liquid chromatography-tandem mass spectrometry.

Authors:  Keng Tiong Ng; Helena Rapp-Wright; Melanie Egli; Alicia Hartmann; Joshua C Steele; Juan Eduardo Sosa-Hernández; Elda M Melchor-Martínez; Matthew Jacobs; Blánaid White; Fiona Regan; Roberto Parra-Saldivar; Lewis Couchman; Rolf U Halden; Leon P Barron
Journal:  J Hazard Mater       Date:  2020-05-24       Impact factor: 10.588

Review 8.  Mass spectrometric strategies for the investigation of biomarkers of illicit drug use in wastewater.

Authors:  Félix Hernández; Sara Castiglioni; Adrian Covaci; Pim de Voogt; Erik Emke; Barbara Kasprzyk-Hordern; Christoph Ort; Malcolm Reid; Juan V Sancho; Kevin V Thomas; Alexander L N van Nuijs; Ettore Zuccato; Lubertus Bijlsma
Journal:  Mass Spectrom Rev       Date:  2016-10-17       Impact factor: 10.946

9.  Predicting reversed-phase liquid chromatographic retention times of pesticides by deep neural networks.

Authors:  Julien Parinet
Journal:  Heliyon       Date:  2021-12-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.