Precision of three-dimensional stereo-photogrammetry (3dMD™) in anthropometry of the auricle and its application in microtia reconstruction.

Zung-Chung Chen1, Mohammad Nayef Albdour2, Jesus Ablaza Lizardo2, Ying-An Chen2, Philip Kuo-Ting Chen2.   

Abstract

BACKGROUND: The advent of three-dimensional stereo-photogrammetry in recent years has vastly helped the craniomaxillofacial field improve in terms of preoperative and intraoperative decision making. With regard to the auricle though, there is paucity of research as to the application of this promising technology.
METHODS: A total of 20 normal adult ears were included in this study. Thirteen anthropometric measurements were taken, twice by two plastic surgeons using direct measurement (DM) and through images captured via 3dMD™. The purpose was to compare the reliability of measurements involving the two instruments.
RESULTS: The overall mean absolute differences (MADs) of all ear anthropometries of DM and 3dMD™ were 0.52 mm (range: 0.28-0.72 mm) and 0.27 mm (range: 0.15-0.53 mm), respectively, and the grand mean relative error magnitudes (REMs) were 2.85% (range: 1.01-5.99%) and 1.57% (range: 0.48-3.62%), respectively, across observers. Thus, the precision of all ear anthropometries across observers was high in both methods, but the precision of 3dMD was better than DM irrespective of observers. In addition, the MADs were less than a millimeter across all measurements.
CONCLUSION: The application of three-dimensional technology in microtia surgery for both template production and soft tissue analysis leads to improved planning and satisfactory results with fewer complications. We believe that with further refinement and enhancement, the use of this innovation will pave the way for prefabricated, individualized autologous or biocompatible alloplastic implantable frameworks based on an accurate mirror image of each patient's normal ear in unilateral cases and in bilateral cases, appropriately sized.
Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3dMD™ auricle/ear; Microtia auricular reconstruction; Rapid prototyping; Three-dimensional stereo-photogrammetry

Mesh:

Year:  2015        PMID: 25892285     DOI: 10.1016/j.bjps.2015.02.020

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  3 in total

Review 1.  Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques.

Authors:  Michael P Chae; Warren Matthew Rozen; Robert T Spychal; David J Hunter-Smith
Journal:  Gland Surg       Date:  2016-04

Review 2.  The cutting edge of customized surgery: 3D-printed models for patient-specific interventions in otology and auricular management-a systematic review.

Authors:  Adam Omari; Martin Frendø; Mads Sølvsten Sørensen; Steven Arild Wuyts Andersen; Andreas Frithioff
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-02-15       Impact factor: 2.503

3.  Three-dimensional evaluation of soft tissues in hyperdivergent skeletal class II females in Guangdong.

Authors:  Xueqin Zhang; Jinxuan Zheng; Jianqing Deng; Zhaoxiang Wen; Zhengyuan Chen; Liyi Gan; Liping Wu
Journal:  BMC Med Imaging       Date:  2022-03-29       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.