Literature DB >> 25891799

On-demand ambient ionization of picoliter samples using charge pulses.

Anyin Li1, Adam Hollerbach2, Qingjie Luo3, R Graham Cooks4.   

Abstract

Relay electrospray ionization (rESI) from a capillary containing a sample solution (or from an array of such capillaries) is triggered by charge deposition onto the capillary. Suitable sources of primary ions, besides electrosprays, are plasma ion and piezoelectric discharge plasma sources. With no requirement for physical contact, high-throughput sample screening is enabled by rapidly addressing individual secondary (sample) capillaries. Sub-pL sample volumes can be loaded and sprayed. Polar analytes, including neurotransmitters, phosphopeptides, oligonucleotides, illicit drugs, and pharmaceutical compounds are successfully ionized by rESI with concentration sensitivities (0.1 ppb for acetylcholine) which are similar to nanoESI but absolute sensitivities are orders of magnitude better. Nonpolar analytes (steroids, alkynes) are ionized by rESI using an open-tube secondary capillary and injecting electrolytically generated metal cations from the primary electrospray.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  electrohydrodynamics; electrospray ionization; mass spectrometry; microaspiration; piezoelectric

Year:  2015        PMID: 25891799     DOI: 10.1002/anie.201501895

Source DB:  PubMed          Journal:  Angew Chem Int Ed Engl        ISSN: 1433-7851            Impact factor:   15.336


  7 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Triboelectric nanogenerators for sensitive nano-coulomb molecular mass spectrometry.

Authors:  Anyin Li; Yunlong Zi; Hengyu Guo; Zhong Lin Wang; Facundo M Fernández
Journal:  Nat Nanotechnol       Date:  2017-02-27       Impact factor: 39.213

3.  Structure of faustovirus, a large dsDNA virus.

Authors:  Thomas Klose; Dorine G Reteno; Samia Benamar; Adam Hollerbach; Philippe Colson; Bernard La Scola; Michael G Rossmann
Journal:  Proc Natl Acad Sci U S A       Date:  2016-05-16       Impact factor: 11.205

4.  Considerations for uranium isotope ratio analysis by atmospheric pressure ionization mass spectrometry.

Authors:  Thomas P Forbes; Christopher Szakal
Journal:  Analyst       Date:  2018-12-17       Impact factor: 4.616

Review 5.  Analytical methods for cholesterol quantification.

Authors:  Li-Hua Li; Ewelina P Dutkiewicz; Ying-Chen Huang; Hsin-Bai Zhou; Cheng-Chih Hsu
Journal:  J Food Drug Anal       Date:  2018-10-04       Impact factor: 6.157

6.  Mass spectrometric snapshots for electrochemical reactions.

Authors:  Ran Qiu; Xin Zhang; Hai Luo; Yuanhua Shao
Journal:  Chem Sci       Date:  2016-07-06       Impact factor: 9.825

7.  Nested-channel for on-demand alternation between electrospray ionization regimes.

Authors:  Mengtian Li; Huishan Li; Nicholas R Allen; Taoqing Wang; Linfan Li; Jae Schwartz; Anyin Li
Journal:  Chem Sci       Date:  2020-12-22       Impact factor: 9.825

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.