Literature DB >> 25890774

Minimum 5 year follow-up of multi-segmental lumbar degenerative disease treated with discectomy and the Wallis interspinous device.

Yun-qi Jiang1, Wu Che1, Hui-ren Wang1, Ruo-yu Li1, Xi-lei Li2, Jian Dong1.   

Abstract

We evaluate the clinical effects and radiological findings of the Wallis interspinous device (Zimmer, Warsaw, IN, USA) for the treatment of multi-segmental lumbar degenerative disease after a minimum 5 year follow-up period. A total of 26 adult patients underwent a primary discectomy followed by fixation of the segment with the Wallis interspinous device between December 2007 and August 2008. Twelve men and 14 women with an age range of 43 to 56 years (average: 47.6) were included. The visual analogue scale (VAS) for low back and leg pain, Oswestry Disability Index (ODI), foraminal height (FH), anterior disc height (aDH) and posterior disc height (pDH), range of motion (ROM) and Pfirrmann grades were obtained and compared before and after surgery. The VAS and ODI significantly decreased postoperatively (p < 0.05). The postoperative FH and pDH values increased significantly compared with the preoperative levels (p < 0.01) and the increase in the FH and pDH values remained statistically significant during the follow-up period. There were no statistically significant changes in the aDH values before and after surgery (p > 0.05). Also, there were no statistically significant changes in the ROM and Pfirrmann grade at the instrumented level and at the cephalad-adjacent segment (p>0.05). In our study, no patient underwent further surgery because of a re-prolapse or progression of index level degeneration or adjacent segment disease. The Wallis interspinous device was a useful alternative for treating multi-segmental lumbar degenerative disease and it offered a significant minimum 5 year symptom control.
Copyright © 2015. Published by Elsevier Ltd.

Entities:  

Keywords:  Adjacent segment disease; Degeneration; Interspinous dynamic device; Multi-segmental; Non-fusion; Wallis

Mesh:

Year:  2015        PMID: 25890774     DOI: 10.1016/j.jocn.2014.12.016

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  6 in total

Review 1.  Interspinous implants: are the new implants better than the last generation? A review.

Authors:  Michael Pintauro; Alexander Duffy; Payman Vahedi; George Rymarczuk; Joshua Heller
Journal:  Curr Rev Musculoskelet Med       Date:  2017-06

2.  Expert's comment concerning Grand Rounds case entitled "Rehydration of a degenerated disc on MRI synchronized with transition of Modic changes following stand-alone XLIF" by K. Kita, T. Sakai, M. Abe, Y. Takata and K. Sairyo (Eur Spine J; 2017: doi:10.1007/s00586-017-4945-6).

Authors:  Rishi M Kanna
Journal:  Eur Spine J       Date:  2017-02-01       Impact factor: 3.134

3.  Rehydration of a degenerated disc on MRI synchronized with transition of Modic changes following stand-alone XLIF.

Authors:  Kenichiro Kita; Toshinori Sakai; Mitsunobu Abe; Yoichiro Takata; Koichi Sairyo
Journal:  Eur Spine J       Date:  2017-01-31       Impact factor: 3.134

4.  Preliminary efficacy of inter-spinal distraction fusion which is a new technique for lumbar disc herniation.

Authors:  Hongyu Wei; Hai Tang; Tidong Zhang; Hao Chen; Chunke Dong
Journal:  Int Orthop       Date:  2018-10-23       Impact factor: 3.075

5.  Evaluation of DIAM™ Spinal Stabilization System for lower lumbar disc degenerative disease: A randomized, prospective, single-site study.

Authors:  Barrett S Boody; Joseph D Smucker; Willa Sasso; Justin W Miller; Ryan Snowden; Rick C Sasso
Journal:  J Orthop       Date:  2020-03-27

6.  15-year survivorship analysis of an interspinous device in surgery for single-level lumbar disc herniation.

Authors:  Yoon Joo Cho; Jong-Beom Park; Dong-Gune Chang; Hong Jin Kim
Journal:  BMC Musculoskelet Disord       Date:  2021-12-09       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.