| Literature DB >> 25888866 |
Tuomas Virén1, Janne Heikkilä2, Kimmo Myllyoja3, Kristiina Koskela4, Tapani Lahtinen5, Jan Seppälä6.
Abstract
BACKGROUND: The aim of the present study was to introduce a new restricted tangential volumetric modulated arc therapy (tVMAT) technique for whole breast irradiation and compare its dosimetric properties to other currently used breast cancer radiotherapy techniques.Entities:
Mesh:
Year: 2015 PMID: 25888866 PMCID: PMC4404692 DOI: 10.1186/s13014-015-0392-x
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Figure 1Typical beam arrangements for FinF (A), tIMRT (B), tVMAT (C) and cVMAT (D).
Mean values and standard deviations (n = 10) of the dosimetric parameters for the different techniques studied
|
|
|
|
| |
|---|---|---|---|---|
|
| ||||
| D1cm3 (Gy) | 53.4 ± 0.5 | 53.3 ± 0.4 | 53.7 ± 0.5 | 53.5 ± 0.6 |
| V47.5 (%) | 97.8 ± 0.8 | 98.1 ± 1.0 | 96.3 ± 2.0 | 91.4 ± 2.4 |
| HI | 0.10 ± 0.01 | 0.10 ± 0.01 | 0.12 ± 0.02 | 0.14 ± 0.01 |
| CI | 0.50 ± 0.03 | 0.50 ± 0.04 | 0.45 ± 0.05 | 0.47 ± 0.09 |
|
| ||||
| V20 (%) | 18.1 ± 5.3 | 15.3 ± 4.6 | 21.6 ± 4.0 | 21.4 ± 3.7 |
| V10 (%) | 25.3 ± 5.6 | 23.4 ± 5.6 | 26.2 ± 4.3 | 25.7 ± 3.8 |
| V5 (%) | 36.9 ± 5.4 | 35.5 ± 5.6 | 33.3 ± 4.3 | 32.0 ± 3.6 |
| Mean dose (Gy) | 9.6 ± 2.1 | 8.7 ± 1.7 | 10.9 ± 1.8 | 10.4 ± 1.5 |
|
| ||||
| Mean dose (Gy) | 0.9 ± 0.1 | 1.6 ± 0.7 | 0.7 ± 0.1 | 0.7 ± 0.1 |
|
| ||||
| V30 (%) | 5.7 ± 6.0 | 3.4 ± 3.9 | 13.9 ± 6.8 | 15.2 ± 6.9 |
| V25 (%) | 8.2 ± 6.9 | 5.0 ± 5.3 | 15.4 ± 7.1 | 16.4 ± 7.4 |
| V2 (%) | 60.8 ± 18.8 | 68.4 ± 22.3 | 61.3 ± 14.4 | 57.9 ± 14.4 |
| Mean dose (Gy) | 6.3 ± 3.0 | 5.5 ± 2.9 | 9.1 ± 3.4 | 9.1 ± 3.5 |
|
| ||||
| V30 (%) | 43.1 ± 29.5 | 32.0 ± 27.3 | 67.8 ± 19.9 | 79.7 ± 8.1 |
| V25 (%) | 55.0 ± 27.8 | 40.3 ± 28.4 | 72.2 ± 15.1 | 81.2 ± 7.5 |
| Mean dose (Gy) | 24.3 ± 8.0 | 20.4 ± 8.7 | 34.4 ± 7.0 | 37.9 ± 3.6 |
|
| ||||
| V2 (%) | 10.2 ± 7.0 | 53.0 ± 27.1 | 11.1 ± 5.6 | 7.0 ± 4.8 |
| Mean dose (Gy) | 1.2 ± 0.3 | 2.6 ± 1.2 | 1.0 ± 0.4 | 1.0 ± 0.3 |
|
| ||||
| V53.5 (cm3) | 0.9 ± 1.1 | 0.4 ± 0. 5 | 8.5 ± 15.6 | 1.9 ± 4.1 |
| V2 (%) | 20.3 ± 4.6 | 30.4 ± 8.3 | 17.3 ± 2.8 | 15.9 ± 3.4 |
| Mean dose (Gy) | 3.3 ± 0.5 | 3.8 ± 0.6 | 3.3 ± 0.5 | 3.4 ± 1.1 |
|
| ||||
| Integral Dose (Gydm3) | 105.3 ± 43.4 | 113.5 ± 43.8 | 105.6 ± 43.8 | 99.3 ± 46.5 |
Figure 2Average cumulative DVHs (n = 10) for the four different techniques studied. PTVin (A), contralateral breast (B), left anterior descending coronary artery (C), heart (D), ipsilateral lung (E), and contralateral lung (F).
Figure 3Typical dose distributions for one patient planed with (A) FinF, (B) tIMRT, (C) tVMAT and (D) cVMAT techniques.