| Literature DB >> 25885584 |
Wei Ye1, Hanxu Fu1, Lin Xie1, Lijun Zhou1, Tai Rao1, Qian Wang1, Yuhao Shao1, Jingcheng Xiao1, Dian Kang1, Guangji Wang1, Yan Liang1.
Abstract
This study provided a novel and generally applicable method to determine ziyuglycoside I and ziyuglycoside II in rat plasma based on liquid chromatography with tandem mass spectrometry. A single step of liquid-liquid extraction with n-butanol was utilized, and ginsenoside Rg3 was chosen as internal standard. Final extracts were analyzed based on liquid chromatography with tandem mass spectrometry. Chromatographic separation was achieved using a Thermo Golden C18 column, and the applied gradient elution program allowed for the simultaneous determination of two ziyuglycosides in a one-step chromatographic separation with a total run time of 10 min. The fully validated methodology for both analytes demonstrated high sensitivity (the lower limit of quantitation was 2.0 ng/mL), good accuracy (% RE ≤ ± 15) and precision (% RSD ≤ 15). The average recoveries of both ziyuglycosides and internal standard were all above 75% and no obvious matrix effect was found. This method was then successfully applied to the preclinical pharmacokinetic studies of ziyuglycoside I and ziyuglycoside II. The presently developed methodology would be useful for the preclinical and clinical pharmacokinetic studies for ziyuglycoside I and ziyuglycoside II.Entities:
Keywords: Liquid chromatography; Pharmacokinetics; Tandem mass spectrometry; Ziyuglycoside I; Ziyuglycoside II
Mesh:
Substances:
Year: 2015 PMID: 25885584 DOI: 10.1002/jssc.201500102
Source DB: PubMed Journal: J Sep Sci ISSN: 1615-9306 Impact factor: 3.645