Literature DB >> 25884731

Multiplexed enzyme-free electrochemical immunosensor based on ZnO nanorods modified reduced graphene oxide-paper electrode and silver deposition-induced signal amplification strategy.

Guoqiang Sun1, Lina Zhang2, Yan Zhang1, Hongmei Yang1, Chao Ma1, Shenguang Ge2, Mei Yan3, Jinghua Yu1, Xianrang Song4.   

Abstract

Herein, an origami multiplexed enzyme-free electrochemical (EC) immunodevice is developed for the first time. Typically, ZnO nanorods (ZNRs) modified reduced graphene oxide (rGO)-paper electrode is used as a sensor platform, in which rGO improves the electronic transmission rate and ZNRs provide abundant sites for capture probes binding. Furthermore, by combining the large surface area of rGO and high catalytic activity of bovine serum protein (BSA)-stabilized silver nanoparticles (Ag@BSA) toward H2O2 reduction, rGO/Ag@BSA composites can be used as an excellent signal labels. The current signal is generated from the reduction of H2O2 and further amplified by a subsequent signal labels-promoted deposition of silver. Under optimal conditions, the proposed immunoassays exhibit excellent precision, high sensitivity and a wide linear range of 0.002-120 mIU mL(-1) for human chorionic gonadotropin, 0.001-110 ng mL(-1) for prostate-specific antigen, and 0.001-100 ng mL(-1) for carcinoembryonic antigen. The results for real sample analysis demonstrate that the newly constructed immunosensor arrays provide a simple and cost-effective method for clinical applications.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical; Enzyme-free; Multiplexed; Paper electrode; Signal amplification

Mesh:

Substances:

Year:  2015        PMID: 25884731     DOI: 10.1016/j.bios.2015.04.007

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Recent Advances in Electrochemical Immunosensors.

Authors:  Benoît Piro; Steeve Reisberg
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

2.  Multiplex Immunosensor Arrays for Electrochemical Detection of Cancer Biomarker Proteins.

Authors:  Bernard S Munge; Thomas Stracensky; Kathleen Gamez; Dimitri DiBiase; James F Rusling
Journal:  Electroanalysis       Date:  2016-06-07       Impact factor: 3.223

3.  Advances in Multiplexed Paper-Based Analytical Devices for Cancer Diagnosis: A Review of Technological Developments.

Authors:  Nihan Yonet-Tanyeri; Benjamin Z Ahlmark; Steven R Little
Journal:  Adv Mater Technol       Date:  2021-04-21

Review 4.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

Review 5.  Electrochemical Signal Substance for Multiplexed Immunosensing Interface Construction: A Mini Review.

Authors:  Jiejie Feng; Changshun Chu; Zhanfang Ma
Journal:  Molecules       Date:  2022-01-02       Impact factor: 4.411

Review 6.  Graphene-based biosensors for the detection of prostate cancer protein biomarkers: a review.

Authors:  Li Xu; Yanli Wen; Santosh Pandit; Venkata R S S Mokkapati; Ivan Mijakovic; Yan Li; Min Ding; Shuzhen Ren; Wen Li; Gang Liu
Journal:  BMC Chem       Date:  2019-09-03

7.  [Applications of microfluidic paper-based chips in environmental analysis and detection].

Authors:  Yu Zhang; Ji Qi; Feng Liu; Ning Wang; Xiyan Sun; Rong Cui; Jialuo Yu; Jiaming Ye; Ping Liu; Bowei Li; Lingxin Chen
Journal:  Se Pu       Date:  2021-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.