Literature DB >> 25884582

Can ultrasound biomicroscopy be used to predict accommodation accurately?

Viswanathan Ramasubramanian, Adrian Glasser.   

Abstract

PURPOSE: Clinical accommodation testing involves measuring either accommodative optical changes or accommodative biometric changes. Quantifying both optical and biometric changes during accommodation might be helpful in the design and evaluation of accommodation restoration concepts. This study aims to establish the accuracy of ultrasound biomicroscopy (UBM) in predicting the accommodative optical response (AOR) from biometric changes.
METHODS: Static AOR from 0 to 6 diopters (D) stimuli in 1-D steps were measured with infrared photorefraction and a Grand Seiko autorefractor (WR-5100 K; Shigiya Machinery Works Ltd., Hiroshima, Japan) in 26 human subjects aged 21 to 36 years. Objective measurements of accommodative biometric changes to the same stimulus demands were measured from UBM (Vu-MAX; Sonomed Escalon, Lake Success, NY) images in the same group of subjects. AOR was predicted from biometry using linear regressions, 95% confidence intervals, and 95% prediction intervals.
RESULTS: Bland-Altman analysis showed 0.52 D greater AOR with photorefraction than with the Grand Seiko autorefractor. Per-diopter changes in accommodative biometry were: anterior chamber depth (ACD): -0.055 mm/D, lens thickness (LT): +0.076 mm/D, anterior lens radii of curvature (ALRC): -0.854 mm/D, posterior lens radii of curvature (PLRC): -0.222 mm/D, and anterior segment length (ASL): +0.030 mm/D. The standard deviation of AOR predicted from linear regressions for various biometry parameters were: ACD: 0.24 D, LT: 0.30 D, ALRC: 0.24 D, PLRC: 0.43 D, ASL: 0.50 D.
CONCLUSIONS: UBM measured parameters can, on average, predict AOR with a standard deviation of 0.50 D or less using linear regression. UBM is a useful and accurate objective technique for measuring accommodation in young phakic eyes. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 25884582     DOI: 10.3928/1081597X-20150319-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Prediction of accommodative optical response in prepresbyopic subjects using ultrasound biomicroscopy.

Authors:  Viswanathan Ramasubramanian; Adrian Glasser
Journal:  J Cataract Refract Surg       Date:  2015-05       Impact factor: 3.351

2.  System for on- and off-axis volumetric OCT imaging and ray tracing aberrometry of the crystalline lens.

Authors:  Marco Ruggeri; Siobhan Williams; Bianca Maceo Heilman; Yue Yao; Yu-Cherng Chang; Ashik Mohamed; N Geetha Sravani; Heather Durkee; Cornelis Rowaan; Alex Gonzalez; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

3.  Predicting Accommodative Response Using Paraxial Schematic Eye Models.

Authors:  Viswanathan Ramasubramanian; Adrian Glasser
Journal:  Optom Vis Sci       Date:  2016-07       Impact factor: 1.973

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.