Literature DB >> 25884577

Image quality comparison of two multifocal IOLs: influence of the pupil.

Mari Carmen García-Domene, Adelina Felipe, Cristina Peris-Martínez, Amparo Navea, Jose M Artigas, Álvaro M Pons.   

Abstract

PURPOSE: To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany).
METHODS: The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques.
RESULTS: In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL.
CONCLUSION: The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 25884577     DOI: 10.3928/1081597X-20150319-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

1.  Preclinical metrics to predict through-focus visual acuity for pseudophakic patients.

Authors:  Aixa Alarcon; Carmen Canovas; Robert Rosen; Henk Weeber; Linda Tsai; Kendra Hileman; Patricia Piers
Journal:  Biomed Opt Express       Date:  2016-04-15       Impact factor: 3.732

2.  Optical bench simulation for intraocular lenses using field-tracing technology.

Authors:  Seok Ho Song; In Seok Song; Se Jin Oh; Hyeck-Soo Son; Min Ho Kang
Journal:  PLoS One       Date:  2021-12-15       Impact factor: 3.240

3.  Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses.

Authors:  Ugur Unsal; Gonen Baser
Journal:  J Ophthalmol       Date:  2016-06-01       Impact factor: 1.909

4.  Diffractive multifocal intraocular lens implantation in eyes with a small-diameter pupil.

Authors:  Masayuki Ouchi; Takuya Shiba
Journal:  Sci Rep       Date:  2018-08-03       Impact factor: 4.379

Review 5.  Extended Depth-of-Field Intraocular Lenses: An Update.

Authors:  Piotr Kanclerz; Francesca Toto; Andrzej Grzybowski; Jorge L Alio
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun
  5 in total