Andreas Schaefer1, Bjoern Sill2, Jeannette Schoenebeck3, Yvonne Schneeberger4, Hermann Reichenspurner5, Helmut Gulbins6.
Abstract
BACKGROUND: Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate.Entities:
Mesh:
Year: 2015 PMID: 25880286 PMCID: PMC4377042 DOI: 10.1186/s13019-015-0238-5
Source DB: PubMed Journal: J Cardiothorac Surg ISSN: 1749-8090 Impact factor: 1.637
Procedural data*
| Patient 1 | Patient 2 | Patient 3 | |
|---|---|---|---|
| Pulmonal valve replacement | Medtronic Freestyle 25 mm | Medtronic Freestyle 25 mm | Medtronic Freestyle 25 mm |
| Tricuspid valve replacement | Edwards Perimount 31 mm | Edwards Perimount 29 mm | Edwards Perimount 25 mm |
| Concomitant procedure | Patch plasty of the pulmonal artery bifurcation | Patch plasty of the pulmonal artery bifurcation | Patch plasty of the pulmonal artery bifurcation |
| Operation time (min) | 240 | 180 | 300 |
| Cross clamp time (min) | 102 | 79 | 118 |
| CPB time (min) | 161 | 124 | 195 |
CPB- cardiopulmonal bypass, Min- minutes.
*All surgical procedures were performed with support of ECC via bicaval and aortic canulation.
Figure 1Transthoracic echocardiography and angiography of patient no. 1. A: Transthoracic echocardiography of the degenerated pulmonal valve prosthesis in doppler color flow with signs of stenosis. B: Angiography with stenosis of the proximal and distal anastomoses (see markers) of the bioprosthesis.
Figure 2Transthoracic echocardiography and angiography of patient no. 2. A: Transthoracic echocardiography of the degenerated pulmonal valve prosthesis in continuous wave doppler with signs of stenosis. B: Angiography of the bioprosthesis with stenosis of the proximal anastomosis (see marker).
Figure 3Computed tomography of the thorax with stenosis of the distal anastomosis of the pulmonary valve conduit with a diameter of 14.8 mm.