Literature DB >> 25878022

Endovascular repair of aortic coarctation pseudoaneurysm using an off-label "hourglass" stent-graft configuration.

Young Erben1, Gustavo S Oderich2, Audra A Duncan1.   

Abstract

PURPOSE: To describe an endovascular technique for treating a pseudoaneurysm of the thoracic aorta using an off-label "hourglass" stent-graft configuration. CASE REPORT: A 68-year-old patient with prior open thoracic aorta coarctation repair presented with recurrent coarctation and concurrent enlarging 6-cm bilobed pseudoaneurysm involving the previous anastomosis. There was significant discrepancy in the aortic diameter (measured from wall to wall) proximal to the coarctation (14 mm), at the narrowest segment (8 mm), and distally (23 mm). Endovascular repair included deployment of an inverted iliac limb proximally, followed by an inverted aortic converter distally, giving an "hourglass" configuration. There were no perioperative or stent-graft-related complications at 5-year follow-up. The aneurysm regressed from 61 to 25 mm.
CONCLUSION: The use of inverted stent-grafts can allow tapering and flaring to adapt to discrepant aortic diameters. This technique may be useful in select patients with prior coarctation repair who do not need excessive dilation of the narrow aortic segment.
© The Author(s) 2015.

Entities:  

Keywords:  coarctation; endovascular repair; iliac limb stent-graft; physician-modified device; pseudoaneurysm; recurrent coarctation; reversed stent-graft; stent-graft

Mesh:

Year:  2015        PMID: 25878022     DOI: 10.1177/1526602815581595

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  1 in total

1.  Heart team approach for comprehensive management of aortic coarctation in the adult.

Authors:  Lee Hafen; William P Shutze; Srinivasa Potluri; John J Squiers; J Michael DiMaio; William T Brinkman
Journal:  Ann Cardiothorac Surg       Date:  2022-01
  1 in total