Literature DB >> 25872574

Prospective evaluation of postoperative penile rehabilitation: penile length/girth maintenance 1 year following Coloplast Titan inflatable penile prosthesis.

Gerard D Henry1, Rafael Carrion2, Caroline Jennermann1, Run Wang3.   

Abstract

INTRODUCTION: The most prevalent long-term complaint after successful inflatable penile prosthesis (IPP) surgery is reduction of penile length. The purpose of this study was to evaluate penile measurements in patients whose implantation experience included the aggressive new length measurement technique (NLMT) coupled with postoperative IPP rehabilitation (daily inflation) of the implant for 1 year. Moreover, we aimed to document objective data concerning dimensional changes of the phallus over time. Postoperative IPP rehabilitation has been discussed and presented at meetings, but no multi-institutional prospective data have been published. AIM: Our goal was to assess results using the Coloplast Titan IPP, with NLMT, and postoperative rehabilitation.
METHODS: After IRB approval, we conducted a prospective, three-center study of 40 patients who underwent IPP placement, with NLMT for end organ failure erectile dysfunction with the Coloplast Titan IPP. The patient was instructed to inflate daily for 6 months and then inflate maximally for 1-2 hours daily for 6-12 months. Fifteen penile measurements were taken before and immediately after surgery and at follow-up visits. MAIN OUTCOME MEASURE: Penile length measurements after implantation compared with 12 months postimplantation.
RESULTS: Penile measurement changes were statistically significantly improved at 12 months as compared with immediately postoperative and at 6 months. A total of 64.5% of subjects were satisfied with their length at 1 year, and 74.2% had perceived penile length that was longer (29%) or the same (45.2%) as prior to the surgery; 61.3% and 16.1% of subjects had increased and unchanged satisfaction, respectively, with penile length as compared with prior to IPP surgery. All but two subjects (93.4%) were satisfied with the overall function and dimensions of their IPP.
CONCLUSION: This study suggests using the Coloplast Titan IPP with aggressive cylinder sizing, and a postoperative penile rehabilitation inflation protocol may help optimize patient satisfaction and erectile penile measurements.
© 2015 International Society for Sexual Medicine.

Entities:  

Keywords:  Erectile Dysfunction; Patient Satisfaction; Penile Implants; Penis; Sexual Dysfunction

Mesh:

Year:  2015        PMID: 25872574     DOI: 10.1111/jsm.12833

Source DB:  PubMed          Journal:  J Sex Med        ISSN: 1743-6095            Impact factor:   3.802


  13 in total

Review 1.  A practical overview of considerations for penile prosthesis placement.

Authors:  Landon Trost; Philip Wanzek; George Bailey
Journal:  Nat Rev Urol       Date:  2015-12-01       Impact factor: 14.432

Review 2.  A Review on Penile Length and Girth Issues in Penile Prosthetic Surgery.

Authors:  Courtney Chang; Run Wang
Journal:  Curr Urol Rep       Date:  2021-02-03       Impact factor: 3.092

3.  Manufacturers' data show increasing implanted cylinder sizes and measured corporal lengths in inflatable penile implants.

Authors:  Charles Welliver; Michael Kottwitz; Ardalan E Ahmad; Steven K Wilson; Tobias S Köhler
Journal:  World J Urol       Date:  2015-10-16       Impact factor: 4.226

Review 4.  Inflatable penile prosthesis cylinders out of place during implantation.

Authors:  Steven K Wilson; Jay Simhan; Rafael Carrion
Journal:  Int J Impot Res       Date:  2020-04-30       Impact factor: 2.896

Review 5.  Optimizing Outcomes in the Virgin Penile Implant Patient.

Authors:  Charles Welliver
Journal:  Curr Urol Rep       Date:  2019-02-07       Impact factor: 3.092

6.  Inflatable penile prosthesis implant length with baseline characteristic correlations: preliminary analysis of the PROPPER study.

Authors:  Nelson Bennett; Gerard Henry; Edward Karpman; William Brant; LeRoy Jones; Mohit Khera; Tobias Kohler; Brian Christine; Eugene Rhee; Bryan Kansas; Anthony J Bella
Journal:  Transl Androl Urol       Date:  2017-12

Review 7.  Narrative review of penile prosthetic implant technology and surgical results, including transgender patients.

Authors:  Michael Polchert; Brian Dick; Omer Raheem
Journal:  Transl Androl Urol       Date:  2021-06

Review 8.  Lengthening strategies for Peyronie's disease.

Authors:  Christopher D Gaffney; Matthew J Pagano; Aaron C Weinberg; Alex C Small; Franklin E Kuehas; Paulo H Egydio; Robert J Valenzuela
Journal:  Transl Androl Urol       Date:  2016-06

9.  Patient satisfaction and penile morphology changes with postoperative penile rehabilitation 2 years after Coloplast Titan prosthesis.

Authors:  Michael B Pryor; Rafael Carrion; Run Wang; Gerard Henry
Journal:  Asian J Androl       Date:  2016 Sep-Oct       Impact factor: 3.285

Review 10.  The penoscrotal surgical approach for inflatable penile prosthesis placement.

Authors:  Nikhil K Gupta; Josh Ring; Landon Trost; Steven K Wilson; Tobias S Köhler
Journal:  Transl Androl Urol       Date:  2017-08
View more