Enzyme-based microfluidic chip coupled to graphene electrodes for the detection of D-amino acid enantiomer-biomarkers.

Pilar Batalla1, Aída Martín1, Miguel Ángel López1, María Cristina González1, Alberto Escarpa1.   

Abstract

An electrochemical microfluidic strategy for the separation and enantiomeric detection of D-methionine (D-Met) and D-leucine (D-Leu) is presented. These D-amino acids (D-AAs) act as biomarkers involved in relevant diseases caused by Vibrio cholerae. On a single layout microfluidic chip (MC), highly compatible with extremely low biological sample consumption, the strategy allowed the controlled microfluidic D-AA separation and the specific reaction between D-amino acid oxidase (DAAO) and each D-AA biomarker avoiding the use of additives (i.e., cyclodextrins) for enantiomeric separation as well as any covalent immobilization of the enzyme into the wall channels or on the electrode surface such as in the biosensor-based approaches. Hybrid polymer/graphene-based electrodes were end-channel coupled to the microfluidic system to improve the analytical performance. D-Met and D-Leu were successfully detected becoming this proof-of-the-concept a promising principle for the development of point-of-care (POC) devices for in situ screening of V. cholerae related diseases.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25870911     DOI: 10.1021/acs.analchem.5b00979

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Fabrication of universal serial bus flash disk type microfluidic chip electrophoresis and application for protein analysis under ultra low voltage.

Authors:  Hailin Cong; Xiaodan Xu; Bing Yu; Huwei Liu; Hua Yuan
Journal:  Biomicrofluidics       Date:  2016-03-15       Impact factor: 2.800

Review 2.  Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review.

Authors:  Mukul Sonker; Vishal Sahore; Adam T Woolley
Journal:  Anal Chim Acta       Date:  2017-07-24       Impact factor: 6.558

Review 3.  Point-of-care microfluidic devices for pathogen detection.

Authors:  Behzad Nasseri; Neda Soleimani; Navid Rabiee; Alireza Kalbasi; Mahdi Karimi; Michael R Hamblin
Journal:  Biosens Bioelectron       Date:  2018-05-29       Impact factor: 10.618

4.  A water-stable lanthanide metal-organic framework for fluorimetric detection of ferric ions and tryptophan.

Authors:  Hani Nasser Abdelhamid; Antonio Bermejo-Gómez; Belén Martín-Matute; Xiaodong Zou
Journal:  Mikrochim Acta       Date:  2017-06-13       Impact factor: 5.833

Review 5.  Biosensors for D-Amino Acids: Detection Methods and Applications.

Authors:  Elena Rosini; Paola D'Antona; Loredano Pollegioni
Journal:  Int J Mol Sci       Date:  2020-06-27       Impact factor: 5.923

Review 6.  D-Amino Acids and D-Amino Acid-Containing Peptides: Potential Disease Biomarkers and Therapeutic Targets?

Authors:  Mohamed Abdulbagi; Liya Wang; Orwa Siddig; Bin Di; Bo Li
Journal:  Biomolecules       Date:  2021-11-18

7.  Fine-Tuning Electrokinetic Injections Considering Nonlinear Electrokinetic Effects in Insulator-Based Devices.

Authors:  Abbi Miller; Nicole Hill; Kel Hakim; Blanca H Lapizco-Encinas
Journal:  Micromachines (Basel)       Date:  2021-05-28       Impact factor: 2.891

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.