Literature DB >> 25870436

Radiation exposure to patients and medical staff in hepatic chemoembolisation interventional procedures in Recife, Brazil.

H J Khoury1, W J Garzon2, G Andrade3, N Lunelli2, R Kramer2, V S M de Barros2, A Huda4.   

Abstract

The purpose of this study was to evaluate patient and medical staff absorbed doses received from transarterial chemoembolisation of hepatocellular carcinoma, which is the most common primary liver tumour worldwide. The study was performed in three hospitals in Recife, capital of the state of Pernambuco, located in the Brazilian Northeastern region. Two are public hospitals (A and B), and one is private (C). For each procedure, the number of images, irradiation parameters (kV, mA and fluoroscopy time), the air kerma-area product (PKA) and the cumulative air kerma (Ka,r) at the reference point were registered. The maximum skin dose (MSD) of the patient was estimated using radiochromic film. For the medical staff dosimetry, thermoluminescence dosemeters (TLD-100) were attached next to the eyes, close to the thyroid (above the shielding), on the thorax under the apron, on the wrist and on the feet. The effective dose to the staff was estimated using the algorithm of von Boetticher. The results showed that the mean value of the total PKA was 267.49, 403.83 and 479.74 Gy cm(2) for Hospitals A, B and C, respectively. With regard to the physicians, the average effective dose per procedure was 17 µSv, and the minimum and maximum values recorded were 1 and 41 µSy, respectively. The results showed that the feet received the highest doses followed by the hands and lens of the eye, since the physicians did not use leaded glasses and the equipment had no lead curtain.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 25870436     DOI: 10.1093/rpd/ncv075

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

Review 1.  Dosimetry of Occupational Eye Lens Dose Using a Novel Direct Eye Dosimeter, DOSIRIS, during Interventional Radiology Procedures.

Authors:  Masakazu Hirakawa; Hiroshi Nakatake; Satoru Tsuruta; Shuji Matsuura; Yuushi Motomura; Yoshiki Hiraki; Koshi Mimori; Kousei Ishigami
Journal:  Interv Radiol (Higashimatsuyama)       Date:  2022-07-01

Review 2.  Radiation protection of the eye lens in medical workers--basis and impact of the ICRP recommendations.

Authors:  Stephen Gr Barnard; Elizabeth A Ainsbury; Roy A Quinlan; Simon D Bouffler
Journal:  Br J Radiol       Date:  2016-02-01       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.