Literature DB >> 25869720

Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

T Meirson1, E Orion2, I Avrahami3.   

Abstract

This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses patients׳ specific computational fluid dynamics (CFD) methods to characterize the relevant hemodynamic parameters of patients׳ SVGs. The method was used to compare the hemodynamics of six patient׳s specific model and flow conditions of stented and non-stented SVGs, 12 months post-transplantation. The flow parameters used to characterize the grafts׳ hemodynamics include Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI) and Relative Residence Time (RRT). The effect of stenting was clearly demonstrated by the chosen parameters. SVGs under constriction of VEST were associated with similar spatial average of TAWSS (10.73 vs 10.29 dyn/cm(2)), yet had fewer lesions with low TAWSS, lower OSI (0.041 vs 0.08) and RRT (0.12 vs 0.24), and more uniform flow with less flow discrepancies. In conclusion, the suggested method and parameters well demonstrated the advantage of VEST support. Stenting vein grafts with VEST improved hemodynamic factors which are correlated to graft failure following CABG procedure.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CABG; CFD; Hemodynamics; Saphenous vein; VEST

Mesh:

Year:  2015        PMID: 25869720     DOI: 10.1016/j.jbiomech.2015.03.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

Review 1.  Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures.

Authors:  Timothy C Boire; Daniel A Balikov; Yunki Lee; Christy M Guth; Joyce Cheung-Flynn; Hak-Joon Sung
Journal:  Macromol Rapid Commun       Date:  2016-09-27       Impact factor: 5.734

2.  Study of helical flow inducers with different thread pitches and diameters in vena cava.

Authors:  Ying Chen; Xiaoyan Deng; Xinying Shan; Yubin Xing
Journal:  PLoS One       Date:  2018-01-03       Impact factor: 3.240

3.  Biomechanical Aspects of Closing Approaches in Postcarotid Endarterectomy.

Authors:  Idit Avrahami; Dafna Raz; Oranit Bash
Journal:  Comput Math Methods Med       Date:  2018-10-28       Impact factor: 2.238

4.  The Short-Term Patency Rate of a Saphenous Vein Bridge Using the No-Touch Technique in off-Pump Coronary Artery Bypass Grafting in Vein Harvesting.

Authors:  Teng-Yue Zhao; Ji-Qiang Bu; Jian-Jun Gu; Yu Liu; Wen-Li Zhang; Zi-Ying Chen
Journal:  Int J Gen Med       Date:  2021-06-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.