Literature DB >> 25868634

Comparison of Narrow Band Imaging and Fujinon Intelligent Color Enhancement in Predicting Small Colorectal Polyp Histology.

Hae Yeon Kang1, Young Sun Kim, Seung Joo Kang, Goh Eun Chung, Ji Hyun Song, Sun Young Yang, Seon Hee Lim, Donghee Kim, Joo Sung Kim.   

Abstract

BACKGROUND: There are limited data on the performance of narrow band imaging (NBI) and Fujinon intelligent color enhancement (FICE) for differentiating polyp histologies. AIMS: The aim of this study was to compare the diagnostic performances of NBI and FICE in differentiating neoplastic from non-neoplastic colorectal polyps <10 mm during screening colonoscopy.
METHODS: A total of 955 average-risk adults undergoing screening colonoscopies were randomly allocated to NBI or FICE groups. Four board-certified staff endoscopists without prior experience using NBI or FICE participated. The main outcomes of this study were overall accuracy, sensitivity, and specificity of FICE and NBI in identifying neoplastic polyps.
RESULTS: There was no significant difference in the number of subjects with adenoma between the NBI (143/475, 30.1 %) and FICE groups (139/480, 29.0 %) (after excluding adenoma ≥1 cm) (P > 0.05). The overall accuracy of NBI was 81.0 %, compared with 81.4 % for FICE (P = 0.867). The overall sensitivity and specificity of NBI and FICE were 84.6 and 78.0 % (P = 0.054); 75.1 and 86.5 % (P = 0.009), respectively. For polyps measuring ≤5 mm, the accuracy was 79.4 % for NBI and 80.1 % for FICE (P = 0.835; sensitivity 81.9 vs. 74.5 %, P = 0.064; specificity 75.7 vs. 88.4 %, P = 0.006).
CONCLUSIONS: The overall accuracy of NBI and FICE was similar for differentiating small polyp histologies during screening colonoscopy. However, better results should be achieved before using NBI or FICE as real-time optical biopsy of colorectal polyps in screening colonoscopy.

Entities:  

Mesh:

Year:  2015        PMID: 25868634     DOI: 10.1007/s10620-015-3661-5

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  29 in total

1.  Computerized virtual chromoendoscopy versus indigo carmine chromoendoscopy combined with magnification for diagnosis of small colorectal lesions: a randomized and prospective study.

Authors:  Carlos Eduardo Oliveira dos Santos; Júlio Carlos Pereira Lima; César Vivian Lopes; Daniele Malaman; Antônio David Salomão; Adriano Calcagnotto Garcia; Cláudio Rolim Teixeira
Journal:  Eur J Gastroenterol Hepatol       Date:  2010-11       Impact factor: 2.566

2.  Differentiating small polyp histologies using real-time screening colonoscopy with Fuji Intelligent Color Enhancement.

Authors:  Young Sun Kim; Donghee Kim; Su Jin Chung; Min Jung Park; Chan Soo Shin; Sang-Heon Cho; Joo Sung Kim; In Sung Song
Journal:  Clin Gastroenterol Hepatol       Date:  2011-06-06       Impact factor: 11.382

3.  Some diminutive colorectal polyps can be removed and discarded without pathological examination.

Authors:  B Denis; J Bottlaender; A M Weiss; A Peter; G Breysacher; P Chiappa; P Perrin
Journal:  Endoscopy       Date:  2010-11-24       Impact factor: 10.093

4.  A prospective comparative study of narrow-band imaging, chromoendoscopy, and conventional colonoscopy in the diagnosis of colorectal neoplasia.

Authors:  Han-Mo Chiu; Chi-Yang Chang; Chien-Chuan Chen; Yi-Chia Lee; Ming-Shiang Wu; Jaw-Town Lin; Chia-Tung Shun; Hsiu-Po Wang
Journal:  Gut       Date:  2006-09-27       Impact factor: 23.059

5.  Colorectal tumours and pit pattern.

Authors:  S Kudo; S Hirota; T Nakajima; S Hosobe; H Kusaka; T Kobayashi; M Himori; A Yagyuu
Journal:  J Clin Pathol       Date:  1994-10       Impact factor: 3.411

6.  Accuracy of narrow-band imaging in predicting colonoscopy surveillance intervals and histology of distal diminutive polyps: results from a multicenter, prospective trial.

Authors:  Alessandro Repici; Cesare Hassan; Franco Radaelli; Pietro Occhipinti; Claudio De Angelis; Fabio Romeo; Silvia Paggi; Silvia Saettone; Fabio Cisarò; Manon Spaander; Prateek Sharma; Ernst J Kuipers
Journal:  Gastrointest Endosc       Date:  2013-04-11       Impact factor: 9.427

7.  Comparison of white light and narrow band high definition images in predicting colon polyp histology, using standard colonoscopes without optical magnification.

Authors:  S Sikka; D A Ringold; S Jonnalagadda; B Banerjee
Journal:  Endoscopy       Date:  2008-07-30       Impact factor: 10.093

8.  A randomized crossover open trial of the adenoma miss rate for narrow band imaging (NBI) versus flexible spectral imaging color enhancement (FICE).

Authors:  Yukinaga Yoshida; Koji Matsuda; Kazuki Sumiyama; Yosuke Kawahara; Kai Yoshizawa; Haruya Ishiguro; Hisao Tajiri
Journal:  Int J Colorectal Dis       Date:  2013-06-29       Impact factor: 2.571

9.  Computed virtual chromoendoscopy versus standard colonoscopy with targeted indigocarmine chromoscopy: a randomised multicentre trial.

Authors:  J Pohl; E Lotterer; C Balzer; M Sackmann; K-D Schmidt; L Gossner; C Schaab; T Frieling; M Medve; G Mayer; M Nguyen-Tat; C Ell
Journal:  Gut       Date:  2008-10-06       Impact factor: 23.059

10.  Narrow band imaging to differentiate neoplastic and non-neoplastic colorectal polyps in real time: a meta-analysis of diagnostic operating characteristics.

Authors:  Sarah K McGill; Evangelos Evangelou; John P A Ioannidis; Roy M Soetikno; Tonya Kaltenbach
Journal:  Gut       Date:  2013-01-07       Impact factor: 23.059

View more
  2 in total

1.  FICE in Predicting Colorectal Flat Lesion Histology.

Authors:  Cevher Akarsu; Nuri A Sahbaz; Ahmet C Dural; Osman Kones; Sinan Binboga; Hamit A Kabuli; Alpen Y Gumusoglu; Halil Alis
Journal:  JSLS       Date:  2017 Oct-Dec       Impact factor: 2.172

Review 2.  Can technology increase adenoma detection rate?

Authors:  Wee Sing Ngu; Colin Rees
Journal:  Therap Adv Gastroenterol       Date:  2018-01-10       Impact factor: 4.409

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.