Literature DB >> 25867519

Pressure relief with visco-elastic foam or with combined static air overlay? A prospective, crossover randomized clinical trial in a dutch nursing home.

Martin van Leen1, Steven Hovius2, Ruud Halfens3, Jacques Neyens4, Jos Schols3.   

Abstract

OBJECTIVE: Evidence of the best mattress for preventing pressure ulcers is not conclusive. In a single center, prospective, crossover trial on pressure ulcer incidence in nursing home residents, a static air overlay mattress, without a pump, on top of a visco-elastic foam mattress was compared with a visco-elastic foam mattress alone.
METHODS: The study was performed using a randomized crossover design. Forty-one patients with a score of 19 or lower on the Braden scale, but with no pressure ulcer at the start, were divided into 2 groups; 21 patients received a visco-elastic foam mattress (control group) and 20 patients a static air overlay on top of a visco-elastic foam mattress (intervention group) for a period of 6 months. In the second (crossover) period of 6 months, 19 patients participated in each group. Patients were checked weekly and, only when signs of development of a pressure ulcer were present was treatment altered to reposition patients according to the nursing home pressure ulcer protocol. No statistically significant differences were noted between the 2 groups with regard to age, gender, or Braden scale score.
RESULTS: Of 41 patients, 3 died and were unable to participate in the crossover period, 8 patients (22.2%) developed a category 2 or higher pressure ulcer on a visco-elastic foam mattress (control group) and 2 (5.2%) on a static air mattress (intervention group)(P = 0.087). There was a difference regarding pressure ulcer incidence between patients with a very low Braden score between 6 and 12, and patients with a mean score between 13-19. Out of 8 patients, in the 2(25%) who developed a pressure ulcer on a foam mattress, the ulcers showed no signs of healing. In the static air group all pressure ulcers healed by normal treatment according to a standardized pressure ulcer treatment protocol.
CONCLUSIONS: In this small study, static air overlay mattresses provided a better prevention than visco-elastic foam mattresses alone (5.2% vs 22.2%). The Braden scores of the patients in both groups did not change during the 6-month test. The decision to use repositioning only when there were signs of a pressure ulcer is acceptable when a static air overlay is in position. The 22.2% incidence of pressure ulcers in the foam group, however, may stress the need to continue repositioning when using this type of mattress. .

Entities:  

Year:  2013        PMID: 25867519

Source DB:  PubMed          Journal:  Wounds        ISSN: 1044-7946            Impact factor:   1.546


  10 in total

1.  Pressure ulcer Cat. II-IV incidence on the CuroCell S.A.M. PRO powered reactive air support surface in a high-risk population: A multicentre cohort study in 12 Belgian nursing homes.

Authors:  Elien Zwaenepoel; Ann Van Hecke; Bénédicte Manderlier; Sofie Verhaeghe; Dimitri Beeckman
Journal:  Int Wound J       Date:  2019-11-11       Impact factor: 3.315

Review 2.  Prevention of pressure ulcers with a static air support surface: A systematic review.

Authors:  Brecht Serraes; Martin van Leen; Jos Schols; Ann Van Hecke; Sofie Verhaeghe; Dimitri Beeckman
Journal:  Int Wound J       Date:  2018-03-05       Impact factor: 3.315

3.  Alternating pressure (active) air surfaces for preventing pressure ulcers.

Authors:  Chunhu Shi; Jo C Dumville; Nicky Cullum; Sarah Rhodes; Asmara Jammali-Blasi; Elizabeth McInnes
Journal:  Cochrane Database Syst Rev       Date:  2021-05-10

4.  Alternative reactive support surfaces (non-foam and non-air-filled) for preventing pressure ulcers.

Authors:  Chunhu Shi; Jo C Dumville; Nicky Cullum; Sarah Rhodes; Elizabeth McInnes
Journal:  Cochrane Database Syst Rev       Date:  2021-05-06

5.  Beds, overlays and mattresses for treating pressure ulcers.

Authors:  Chunhu Shi; Jo C Dumville; Nicky Cullum; Sarah Rhodes; Asmara Jammali-Blasi; Victoria Ramsden; Elizabeth McInnes
Journal:  Cochrane Database Syst Rev       Date:  2021-05-10

6.  Reactive air surfaces for preventing pressure ulcers.

Authors:  Chunhu Shi; Jo C Dumville; Nicky Cullum; Sarah Rhodes; Vannessa Leung; Elizabeth McInnes
Journal:  Cochrane Database Syst Rev       Date:  2021-05-07

7.  What is the better choice for nurses? Alternating air pressure mattresses versus static air mattresses to prevent pressure ulcers in elderly hospitalized patients: A protocol for systematic review and meta-analysis.

Authors:  Yinxi Li; Xuemei Zeng; Jianyuan Wang; Chunlei Wang
Journal:  Medicine (Baltimore)       Date:  2022-04-01       Impact factor: 1.817

Review 8.  Pressure Relief, Visco-Elastic Foam with Inflated Air? A Pilot Study in a Dutch Nursing Home.

Authors:  Martin Van Leen; Jos Schols
Journal:  Healthcare (Basel)       Date:  2015-02-12

9.  A Comparative Study Between Two Support Surfaces for Pressure Ulcer Prevention and Healing in ICU Patients.

Authors:  Aikaterini Marvaki; Georgia Kourlaba; Olga Kadda; Georgios Vasilopoulos; Nikoleta Rovina; Antonia Koutsoukou; Anastasia Kotanidou
Journal:  Cureus       Date:  2020-06-23

10.  Foam surfaces for preventing pressure ulcers.

Authors:  Chunhu Shi; Jo C Dumville; Nicky Cullum; Sarah Rhodes; Elizabeth McInnes
Journal:  Cochrane Database Syst Rev       Date:  2021-05-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.