Literature DB >> 25864402

Effect of Irrigant Characteristics on Lesion Formation After Radiofrequency Energy Delivery Using Ablation Catheters with Actively Cooled Tips.

Duy T Nguyen1, Matthew Olson1, Lijun Zheng1, Waseem Barham1, Joshua D Moss2, William H Sauer1.   

Abstract

BACKGROUND: The delivery of radiofrequency (RF) energy through irrigated ablation catheters may be affected by irrigant osmolarity and by catheter position. We sought to characterize lesion formation characteristics using different irrigants in both open and closed irrigated catheter.
METHODS: An ex vivo model consisting of viable bovine myocardium and a submersible load cell was assembled in a circulating saline bath at 37°C. An externally irrigated ablation catheter and a closed irrigated catheter were positioned with 10 g of force in both perpendicular and parallel positions. A series of ablation lesions using different irrigants were delivered using a constant rate of irrigation (30 cc/min) at 50 W. Potential clinical applicability was evaluated in vivo by targeting porcine epicardium with different irrigants during open irrigation ablation and assessing lesion sizes.
RESULTS: Ablation in the perpendicular position produced significantly larger lesions for all irrigants, compared to their respective parallel position ablation. For both open and closed irrigated ablation, half normal saline (HNS) ablation created larger lesions than normal saline (NS), and dextrose water (D5W) lesions were significantly larger than both HNS and NS lesions. Steam pops were mostly observed in the perpendicular position, and the rate of steam pops was statistically higher only for open irrigated D5W, but not for HNS, when compared to NS. Both open and closed irrigated ablation with D5W and HNS in the parallel position created larger lesions than parallel NS ablation without causing more steam pops. In an in vivo porcine model, open irrigated ablation with D5W created larger lesions compared to standard NS irrigation.
CONCLUSIONS: In ex vivo and in vivo models, decreased osmolarity and charge density increased RF energy delivery to tissue, resulting in larger lesions for both open and closed irrigated ablations. A perpendicular catheter position created larger lesions across all irrigants for both open and closed irrigation ablation. The incidence of steam pops was observed more frequently with high power open irrigated using D5W, especially if the catheter was in a perpendicular position. Further research is required to evaluate any clinical role for using different irrigants with an externally irrigated catheter.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  Smart Touch catheter; catheter ablation; contact force; experimental study; irrigated catheter tip; ventricular tachycardia

Mesh:

Substances:

Year:  2015        PMID: 25864402     DOI: 10.1111/jce.12682

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  20 in total

1.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

2.  Novel Irrigated Temperature-Controlled Lattice Ablation Catheter for Ventricular Ablation: A Preclinical Multimodality Biophysical Characterization.

Authors:  Ayelet Shapira-Daniels; Michael Barkagan; Hagai Yavin; Jakub Sroubek; Vivek Y Reddy; Petr Neuzil; Elad Anter
Journal:  Circ Arrhythm Electrophysiol       Date:  2019-11-11

3.  Retrograde Coronary Venous Ethanol Infusion for Ablation of Refractory Ventricular Tachycardia.

Authors:  Bahij Kreidieh; Moisés Rodríguez-Mañero; Paul Schurmann; Sergio Hugo Ibarra-Cortez; Amish S Dave; Miguel Valderrábano
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-07

4.  Relationship Between Ablation Lesion Size Estimated by Ablation Index and Different Ablation Settings-an Ex Vivo Porcine Heart Study.

Authors:  Shu-Tao Huang; Jian-Zeng Dong; Xin Du; Jia-Hui Wu; Rong-Hui Yu; De-Yong Long; Man Ning; Cai-Hua Sang; Chen-Xi Jiang; Rong Bai; Song-Nan Wen; Nian Liu; Song-Nan Li; Wei Wang; Xue-Yuan Guo; Xin Zhao; Xuan Chen; Yi-Kai Cui; Ri-Bo Tang; Chang-Sheng Ma
Journal:  J Cardiovasc Transl Res       Date:  2020-06-02       Impact factor: 4.132

5.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Sáenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

Review 6.  Radiofrequency Ablation Strategies for Intramural Ventricular Arrhythmias.

Authors:  Naga Venkata K Pothineni; Fermin C Garcia; Pasquale Santangeli
Journal:  Methodist Debakey Cardiovasc J       Date:  2021-03-25

Review 7.  [Update on ablation of ventricular tachyarrhythmias].

Authors:  Shibu Mathew; Patrick Müller; Carina Hardy; Mauricio Ibrahim Scanavacca; Thomas Deneke
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-02-14

8.  Clinical efficacy of irrigated catheter application of amiodarone during ablation of persistent atrial fibrillation.

Authors:  Xingfu Huang; Yanjia Chen; Yuli Huang; Hongxin Zhao; Yanyu Chen; Liwei He; Shenrong Liu; Vikram Shee; Dingli Xu; Jian Peng
Journal:  Clin Cardiol       Date:  2017-12-16       Impact factor: 2.882

Review 9.  Contemporary Tools and Techniques for Substrate Ablation of Ventricular Tachycardia in Structural Heart Disease.

Authors:  Mathew D Hutchinson; Hyon-He K Garza
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-02-24

10.  Impact of Variableorientation and Flow Rates on Radiofrequency Ablation Lesions Created by Externally Irrigated Catheters: An Ex-Vivo Study.

Authors:  Nishaki Mehta; Katerina Morgaenko; William Sauer; William Stevenson; David Haines
Journal:  J Atr Fibrillation       Date:  2020-10-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.