| Literature DB >> 25864013 |
Shuanghu Wang1, Haiya Wu2, Xueli Huang3, Peiwu Geng1, Congcong Wen3, Jianshe Ma3, Yunfang Zhou4, Xianqin Wang5.
Abstract
In this work, a sensitive and selective UPLC-MS/MS method for determination of N-methylcytisine in rat plasma is developed. After addition of hordenine as an internal standard (IS), protein precipitation by acetonitrile-methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH HILIC (2.1 mm×100mm, 1.7μm) with acetonitrile (containing 10mM ammonium formate) and water (containing 0.1% formic acid and 10mM ammonium formate) as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring (MRM) mode was used for quantification using target fragment ions m/z 205.1→58.0 for N-methylcytisine, and m/z 166.1→121.0 for IS. Calibration plots were linear throughout the range 2-2000ng/mL for N-methylcytisine in rat plasma. Mean recoveries of N-methylcytisine in rat plasma ranged from 86.1% to 94.8%. RSD of intra-day and inter-day precision were both<13%. The accuracy of the method was between 94.5% and 109.4%. The method was successfully applied to pharmacokinetic study of N-methylcytisine after either oral or intravenous administration. For the first time, the absolute bioavailability of N-methylcytisine was reported as high as 55.5%.Entities:
Keywords: N-methylcytisine; UPLC-MS/MS; pharmacokinetics; rat plasma
Mesh:
Substances:
Year: 2015 PMID: 25864013 DOI: 10.1016/j.jchromb.2015.03.025
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205