Literature DB >> 25861534

An alternative instrument for making entry point for elastic intramedullary nail.

P Sharma1, S Meena1, S Gangary2, B Chowdhury1.   

Abstract

Femoral shaft fractures are common in children and are increasingly being treated with elastic intramedullary nail. We outline an instrument we have used successfully to make an entry point for placement of elastic nail.

Entities:  

Keywords:  Elastic nailing; Fracture shaft femur; Technique

Year:  2015        PMID: 25861534      PMCID: PMC4389329          DOI: 10.4103/2141-9248.153624

Source DB:  PubMed          Journal:  Ann Med Health Sci Res        ISSN: 2141-9248


Introduction

Femoral shaft fracture is a common major pediatric orthopedic injury that most orthopedic surgeons treat routinely.[1] These fractures have traditionally been treated nonoperatively with early spica cast or a period of traction followed by application of hip spica cast until the fracture unites. Internal fixation of pediatric shaft femur fracture by elastic stable intramedullary nail is gradually replacing conservative treatment[2] and over the past two decades the advantages of fixation of pediatric femoral shaft fractures by elastically stable intramedullary nails have been increasingly accepted.[3] The most common complication with titanium elastic nail is skin irritation at nail entry point due to protruded nail. Other complications include mal-union of fracture, shortening and lengthening of a limb due to inadequate axial and bending stability in communited, spiral and oblique fracture. Stiffness of knee and painful bursa formation over the nail tip are other complications.[45] Despite all these complications, the flexible nail is being increasingly used because it allows early mobilization of patient, the complications are minor and could be addressed easily and that it gives freedom from cumbersome conservative management appliance and necessities such as hip spica cast, thomas splint, tractional devices and prolonged bed recumbency. Furthermore, the elastic nail insertion technique is easy with short learning curve and complication profile is favorable when compared with plating, a solid antegrade nail, and external fixator in skeletally immature patient.[6] Titanium flexible intramedullary nail is usually inserted in a retrograde manner. The entry points are made just proximal to the growth plate in distal metaphysis of the femur each on medial and lateral side. Conventionally, the entry point is made with a 4.5 or 3.2 mm drill bit or using an awl, 2 cm proximal to the growth plate in the distal metaphyseal area of the femur.[67] Making an oblique entry point with a straight 4.5 mm drill bit is difficult because it jumps over the cortex and it may results in missing of desired correct site of entry point and sometime may lead to breakage of drill bit. The repeated use of the awl may make it tip blunt, and one may find difficulty in making the entry point with the awl. Sometimes, inadvertent fall of instrument on the floor from the operation table makes the instrument unsterile, and this may lead the surgeon into temporary despair. The awl may not be available in rural setting. In this scenario, we improvised a method to make a correct oblique entry point without any difficult. We describe here an instrument we have used successfully to make an entry point for placement of elastic nail.

Technical Note

We suggest the use of trocar of the vacuum suction drain to make the entry point. The trocar can be attached to the T-handle and with a gentle rotatory movement a relatively longitudinal entry point can be made, which facilitate easy nail insertion [Figures 1 and 2]. The trocar is curved, sharp and of adequate thickness that make it easier for the surgeon to make the entry hole. The children's bones are soft and can be penetrated easily by the sharp trocar. Owing to a disposable nature of the needle, every time a fresh trocar with a sharp tip can be used.
Figure 1

Curved trocar of vacuum suction set

Figure 2

Entry point being created by attaching the tip to the T handle

Curved trocar of vacuum suction set Entry point being created by attaching the tip to the T handle

Discussion

The advantages of using this new instrument are as follows; better control over making entry point due to solid construct and symmetrical width of its whole length, cost effective, no chances of slipping and break down of drill bit, time saving because no need of using drill bit prior to awl, easily available in even peripheral operation theatres, light weight so durable as comparative to drill assembly and no need of power and battery as manual power used for working without any maintenance due to disposable nature.
  6 in total

1.  Elastic stable intramedullary nailing of femoral shaft fractures in children.

Authors:  J N Ligier; J P Metaizeau; J Prévot; P Lascombes
Journal:  J Bone Joint Surg Br       Date:  1988-01

Review 2.  Intramedullary nailing of pediatric femoral shaft fracture.

Authors:  Harish S Hosalkar; Nirav K Pandya; Robert H Cho; Diana A Glaser; Molly A Moor; Martin J Herman
Journal:  J Am Acad Orthop Surg       Date:  2011-08       Impact factor: 3.020

3.  Titanium elastic nails for pediatric femur fractures: a multicenter study of early results with analysis of complications.

Authors:  J M Flynn; T Hresko; R A Reynolds; R D Blasier; R Davidson; J Kasser
Journal:  J Pediatr Orthop       Date:  2001 Jan-Feb       Impact factor: 2.324

Review 4.  Stable elastic intramedullary nailing for fractures of the femur in children.

Authors:  J P Metaizeau
Journal:  J Bone Joint Surg Br       Date:  2004-09

5.  Femoral shaft fractures in children: elastic stable intramedullary nailing in 31 cases.

Authors:  Shirzad Houshian; Charlotte Buch Gøthgen; Niels Wisbech Pedersen; Søren Harving
Journal:  Acta Orthop Scand       Date:  2004-06

Review 6.  Management of pediatric femoral shaft fractures.

Authors:  John M Flynn; Richard M Schwend
Journal:  J Am Acad Orthop Surg       Date:  2004 Sep-Oct       Impact factor: 3.020

  6 in total
  1 in total

1.  An Alternative Instrument for Making Entry Point for Elastic Intramedullary Nail.

Authors:  G S Dharmshaktu; I Khan
Journal:  Ann Med Health Sci Res       Date:  2016 May-Jun
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.