Literature DB >> 25858299

Tracking camera control in endoscopic dacryocystorhinostomy surgery.

J R Wawrzynski1, P Smith2, L Tang2, T Hoare1, S Caputo3, A A Siddiqui4, M Tsatsos3, G M Saleh3,5,6.   

Abstract

OBJECTIVES: Poor camera control during endoscopic dacryocystorhinostomy (EnDCR) surgery can cause inadequate visualisation of the anatomy and suboptimal surgical outcomes. This study investigates the feasibility of using computer vision tracking in EnDCR surgery as a potential formative feedback tool for the quality of endoscope control.
DESIGN: A prospective cohort analysis was undertaken comparing junior versus senior surgeons performing routine EnDCR surgery. Computer vision tracking was applied to endoscopic video footage of the surgery: Total number of movements, camera path length in pixels and surgical time were determined for each procedure. A Mann-Whitney U-test was used to test for a significant difference between juniors and seniors (P < 0.05).
SETTING: Operating theatre. PARTICIPANTS: Ten junior surgeons (<20 completed procedures) and 10 senior surgeons (>100 completed procedures). MAIN OUTCOME MEASURES: Total number of movements of the endoscope per procedure. Path length of the endoscope per procedure.
RESULTS: Twenty videos, 10 from junior surgeons and 10 from senior surgeons were analysed. Feasibility of our tracking system was demonstrated. Mean camera path lengths were significantly different at 119,329px (juniors) versus 43,697px (seniors), P ≪ 0.05. The mean number of movements was significantly different at 9134 (juniors) versus 3690 (seniors), P ≪ 0.05. These quantifiable differences demonstrate construct validity for computer vision endoscope tracking as a measure of surgical experience.
CONCLUSIONS: Computer vision tracking is a potentially useful structured and objective feedback tool to assist trainees in improving endoscope control. It enables juniors to examine how their pattern of endoscope control differs from that of seniors, focusing in particular on sections where they are most divergent.
© 2015 John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2015        PMID: 25858299     DOI: 10.1111/coa.12433

Source DB:  PubMed          Journal:  Clin Otolaryngol        ISSN: 1749-4478            Impact factor:   2.597


  1 in total

1.  Man versus Machine: Software Training for Surgeons-An Objective Evaluation of Human and Computer-Based Training Tools for Cataract Surgical Performance.

Authors:  Nizar Din; Phillip Smith; Krisztina Emeriewen; Anant Sharma; Simon Jones; James Wawrzynski; Hongying Tang; Paul Sullivan; Silvestro Caputo; George M Saleh
Journal:  J Ophthalmol       Date:  2016-10-27       Impact factor: 1.909