Literature DB >> 25857616

Electropolymerized phenol derivatives as permselective polymers for biosensor applications.

Giammario Calia1, Patrizia Monti, Salvatore Marceddu, Maria A Dettori, Davide Fabbri, Samir Jaoua, Robert D O'Neill, Pier A Serra, Giovanna Delogu, Quirico Migheli.   

Abstract

Amperometric biosensors are often coated with a polymeric permselective film to avoid electroactive interference by reducing agents present in the target medium. Phenylenediamine and phenol monomers are commonly used to form these permselective films in the design of microsensors and biosensors. This paper aims to evaluate the permselectivity, stability and lifetime of polymers electrosynthesized using either constant potential amperometry (CPA) or cyclic voltammetry (CV) from naturally occurring phenylpropanoids in monomeric and dimeric forms (eugenol, isoeugenol, dehydrodieugenol and magnolol). Sensors were characterized by scanning electron microscopy and permselectivity analysis. Magnolol formed an electro-deposited polymer with a more defined three-dimensional texture in comparison with the other films. The phenol-derived films showed different permselectivity towards H2O2 over ascorbic acid and dopamine, likely to be related to the thickness and compactness of the polymer. The CV-derived films had a better permselectivity compared to the CPA-corresponding polymers. Based on these results, the permselectivity, stability and lifetime of a biosensor for glucose were studied when a magnolol coating was electro-deposited. The structural principles governing the permselectivity of the magnolol-derived film are suggested to be mainly related to the conformational flexibility of this monomer. Newly designed biosensors, coated with electropolymerized natural phenol derivatives, may represent promising analytical devices for different application fields.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25857616     DOI: 10.1039/c5an00363f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Nitric oxide permselectivity in electropolymerized films for sensing applications.

Authors:  Micah D Brown; Mark H Schoenfisch
Journal:  ACS Sens       Date:  2016-11-16       Impact factor: 7.711

2.  A direct and selective electrochemical hydrogen sulfide sensor.

Authors:  Micah D Brown; Jackson R Hall; Mark H Schoenfisch
Journal:  Anal Chim Acta       Date:  2018-09-01       Impact factor: 6.558

Review 3.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

4.  Characterization of Biosensors Based on Recombinant Glutamate Oxidase: Comparison of Crosslinking Agents in Terms of Enzyme Loading and Efficiency Parameters.

Authors:  Rochelle Ford; Susan J Quinn; Robert D O'Neill
Journal:  Sensors (Basel)       Date:  2016-09-23       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.