Literature DB >> 25856110

Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging.

Gregory W Albert1, Charles M Glasier.   

Abstract

BACKGROUND: Radiation exposure from diagnostic imaging is a significant concern, particularly in the care of pediatric patients. Computed tomography (CT) scanning is a significant source of radiation.
OBJECTIVE: To demonstrate that diagnostic quality CT images can be obtained while minimizing the effective radiation dose to the patient.
METHODS: In this retrospective cross-sectional study, noncontrast head CT scan data were reviewed, and indications for scans and estimated radiation dose delivered were recorded. The estimated effective radiation dose (EERD) for each CT protocol was reviewed.
RESULTS: We identified 251 head CT scans in a single month. Of these, 96 scans were using a low-dose shunt protocol with a mean EERD of 0.82 mSv. The remaining 155 scans were performed using the standard protocol, and the mean EERD was 1.65 mSv. Overall, the EERD was minimized while maintaining diagnostic scan quality.
CONCLUSION: Although replacing a CT with magnetic resonance imaging is ideal to completely avoid ionizing radiation, this is not always practical or preferred. Therefore, it is important to have CT protocols in place that minimize radiation dose without sacrificing diagnostic quality. The protocols in place at our institution could be replicated at other academic and community hospitals and imaging centers.

Entities:  

Mesh:

Year:  2015        PMID: 25856110     DOI: 10.1227/NEU.0000000000000764

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  2 in total

1.  [Imaging after trauma in clinics and practice for children and adolescents : Part 1 of the results of a nationwide online survey of the Pediatric Traumatology Section of the German Trauma Society].

Authors:  Klaus Dresing; Ralf Kraus; Francisco Fernandez; Peter Schmittenbecher; Kaya Dresing; Peter Strohm; Christopher Spering
Journal:  Unfallchirurg       Date:  2021-12-16       Impact factor: 1.000

2.  Development and validation of image quality scoring criteria (IQSC) for pediatric CT: a preliminary study.

Authors:  Atul M Padole; Pallavi Sagar; Sjirk J Westra; Ruth Lim; Katherine Nimkin; Mannudeep K Kalra; Michael S Gee; Madan M Rehani
Journal:  Insights Imaging       Date:  2019-09-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.