Literature DB >> 25856087

Skin image illumination modeling and chromophore identification for melanoma diagnosis.

Zhao Liu1, Josiane Zerubia.   

Abstract

The presence of illumination variation in dermatological images has a negative impact on the automatic detection and analysis of cutaneous lesions. This paper proposes a new illumination modeling and chromophore identification method to correct lighting variation in skin lesion images, as well as to extract melanin and hemoglobin concentrations of human skin, based on an adaptive bilateral decomposition and a weighted polynomial curve fitting, with the knowledge of a multi-layered skin model. Different from state-of-the-art approaches based on the Lambert law, the proposed method, considering both specular reflection and diffuse reflection of the skin, enables us to address highlight and strong shading effects usually existing in skin color images captured in an uncontrolled environment. The derived melanin and hemoglobin indices, directly relating to the pathological tissue conditions, tend to be less influenced by external imaging factors and are more efficient in describing pigmentation distributions. Experiments show that the proposed method gave better visual results and superior lesion segmentation, when compared to two other illumination correction algorithms, both designed specifically for dermatological images. For computer-aided diagnosis of melanoma, sensitivity achieves 85.52% when using our chromophore descriptors, which is 8~20% higher than those derived from other color descriptors. This demonstrates the benefit of the proposed method for automatic skin disease analysis.

Entities:  

Mesh:

Year:  2015        PMID: 25856087     DOI: 10.1088/0031-9155/60/9/3415

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Screening neonatal jaundice based on the sclera color of the eye using digital photography.

Authors:  Terence S Leung; Karan Kapur; Ashley Guilliam; Jade Okell; Bee Lim; Lindsay W MacDonald; Judith Meek
Journal:  Biomed Opt Express       Date:  2015-10-23       Impact factor: 3.732

Review 2.  A review of melanin sensor devices.

Authors:  Vangelis George Kanellis
Journal:  Biophys Rev       Date:  2019-08-08

3.  Three-dimensional representation of triple spectral line imaging data as an option for noncontact skin diagnostics.

Authors:  Ilze Ošina; Janis Spigulis; Ilona Kuzmina; Laura Dambite; Anna Berzina
Journal:  J Biomed Opt       Date:  2022-09       Impact factor: 3.758

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.