Literature DB >> 25853386

VO2max Measured with a Self-selected Work Rate Protocol on an Automated Treadmill.

Cory M Scheadler1, Steven T Devor.   

Abstract

PURPOSE: The use of graded maximal exercise tests for measuring maximal oxygen consumption (VO2max) is common practice in both cardiopulmonary rehabilitation settings and in sports medicine research. Recent alterations of common testing protocols to allow for self-selected work rates (SPV) have elicited V˙O2max values similar to or higher than more traditional style protocols (TP). Research is lacking in the delivery of the SPV protocol using a treadmill modality. The purpose of the study was to examine the validity of an SPV using an automated treadmill for measuring cardiorespiratory fitness.
METHODS: Thirteen experienced endurance runners completed three maximal exercise tests on a treadmill. Oxygen consumption was measured using a computerized system and averaged more than 30-s time periods. SPV was completed using an automated treadmill that consisted of a sonar range finder, microcontroller, and customized computer software. Subject deviations from the middle of the treadmill belt resulted in rapid, graded increases or decreases in speed. TP was completed on the same treadmill without the use of the automated software. A verification phase protocol (VP) was used to verify if VO2 was maximal.
RESULTS: Peak work rate achieved during SPV was significantly greater than that achieved during TP by 1.2 METs; P < 0.05, d = 0.564. Oxygen consumption was significantly greater in TP (64.9 ± 8.2 mL·kg·min) than SPV (63.4 ± 7.8 mL·kg·min); P < 0.005, d = 0.195.
CONCLUSION: An automated treadmill allowed for the completion of SPV similar to what has been reported for cycling. SPV with an automated treadmill did not provide a higher VO2max than TP despite higher work rates.

Entities:  

Mesh:

Year:  2015        PMID: 25853386     DOI: 10.1249/MSS.0000000000000647

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  9 in total

1.  Cortical neural arousal is differentially affected by type of physical exercise performed.

Authors:  Nicholas J Hanson; Lindsey E Short; Lauren T Flood; Nicholas P Cherup; Michael G Miller
Journal:  Exp Brain Res       Date:  2018-03-28       Impact factor: 1.972

2.  Modality determines VO2max achieved in self-paced exercise tests: validation with the Bruce protocol.

Authors:  Nicholas J Hanson; Cory M Scheadler; Taylor L Lee; Noah C Neuenfeldt; Timothy J Michael; Michael G Miller
Journal:  Eur J Appl Physiol       Date:  2016-05-05       Impact factor: 3.078

3.  Pacing strategy during the final stage of a self-paced V̇O₂max (SPV) test does not affect maximal oxygen uptake.

Authors:  Nicholas J Hanson; Carter R Reid; Kaitlin M Cornwell; Taylor L Lee; Cory M Scheadler
Journal:  Eur J Appl Physiol       Date:  2017-06-05       Impact factor: 3.078

Review 4.  Submaximal, Perceptually Regulated Exercise Testing Predicts Maximal Oxygen Uptake: A Meta-Analysis Study.

Authors:  Jeremy Coquart; Montassar Tabben; Abdulaziz Farooq; Claire Tourny; Roger Eston
Journal:  Sports Med       Date:  2016-06       Impact factor: 11.136

Review 5.  Graded Exercise Testing Protocols for the Determination of VO2max: Historical Perspectives, Progress, and Future Considerations.

Authors:  Nicholas M Beltz; Ann L Gibson; Jeffrey M Janot; Len Kravitz; Christine M Mermier; Lance C Dalleck
Journal:  J Sports Med (Hindawi Publ Corp)       Date:  2016-12-25

6.  Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.

Authors:  Michael J Hutchinson; Thomas A W Paulson; Roger Eston; Victoria L Goosey-Tolfrey
Journal:  PLoS One       Date:  2017-07-13       Impact factor: 3.240

7.  Prescribing 6-weeks of running training using parameters from a self-paced maximal oxygen uptake protocol.

Authors:  James S Hogg; James G Hopker; Sarah L Coakley; Alexis R Mauger
Journal:  Eur J Appl Physiol       Date:  2018-02-12       Impact factor: 3.078

Review 8.  The Maximal Oxygen Uptake Verification Phase: a Light at the End of the Tunnel?

Authors:  Gustavo Z Schaun
Journal:  Sports Med Open       Date:  2017-12-08

9.  The Reliability and Validity of a Four-Minute Running Time-Trial in Assessing [Formula: see text]max and Performance.

Authors:  Kerry McGawley
Journal:  Front Physiol       Date:  2017-05-03       Impact factor: 4.566

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.