Effects of Temperature, Humidity and Air Flow on Fungal Growth Rate on Loaded Ventilation Filters.

W Tang1, T H Kuehn, Matt F Simcik.   

Abstract

This study compares the fungal growth ratio on loaded ventilation filters under various temperature, relative humidity (RH), and air flow conditions in a controlled laboratory setting. A new full-size commercial building ventilation filter was loaded with malt extract nutrients and conidia of Cladosporium sphaerospermum in an ASHRAE Standard 52.2 filter test facility. Small sections cut from this filter were incubated under the following conditions: constant room temperature and a high RH of 97%; sinusoidal temperature (with an amplitude of 10°C, an average of 23°C, and a period of 24 hr) and a mean RH of 97%; room temperature and step changes between 97% and 75% RH, 97% and 43% RH, and 97% and 11% RH every 12 hr. The biomass on the filter sections was measured using both an elution-culture method and by ergosterol assay immediately after loading and every 2 days up to 10 days after loading. Fungal growth was detected earlier using ergosterol content than with the elution-culture method. A student's t-test indicated that Cladosporium sphaerospermum grew better at the constant room temperature condition than at the sinusoidal temperature condition. By part-time exposure to dry environments, the fungal growth was reduced (75% and 43% RH) or even inhibited (11% RH). Additional loaded filters were installed in the wind tunnel at room temperature and an RH greater than 95% under one of two air flow test conditions: continuous air flow or air flow only 9 hr/day with a flow rate of 0.7 m(3)/s (filter media velocity 0.15 m/s). Swab tests and a tease mount method were used to detect fungal growth on the filters at day 0, 5, and 10. Fungal growth was detected for both test conditions, which indicates that when temperature and relative humidity are optimum, controlling the air flow alone cannot prevent fungal growth. In real applications where nutrients are less sufficient than in this laboratory study, fungal growth rate may be reduced under the same operating conditions.

Entities:  

Keywords:  air flow; fungal growth; humidity; temperature; ventilation filters

Mesh:

Substances:

Year:  2015        PMID: 25849091     DOI: 10.1080/15459624.2015.1019076

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Unveiling hidden energy poverty using the energy equity gap.

Authors:  Shuchen Cong; Destenie Nock; Yueming Lucy Qiu; Bo Xing
Journal:  Nat Commun       Date:  2022-05-04       Impact factor: 17.694

2.  Actual measurement, hygrothermal response experiment and growth prediction analysis of microbial contamination of central air conditioning system in Dalian, China.

Authors:  Yang Lv; Guangyao Hu; Chunyang Wang; Wenjie Yuan; Shanshan Wei; Jiaoqi Gao; Boyuan Wang; Fangchao Song
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

3.  The Importance of Nitric Oxide as the Molecular Basis of the Hydrogen Gas Fumigation-Induced Alleviation of Cd Stress on Ganoderma lucidum.

Authors:  Dyaaaldin Abdalmegeed; Gan Zhao; Pengfei Cheng; Javaid A Bhat; Wajid Ali Khattak; Mostafa G Ali; Fawze Alnadari; Ilyas Ali; Qurban Ali; Sameh A Korma; Yehia A-G Mahmoud; Manar K Abd Elnabi; Weiti Cui; Wenbiao Shen
Journal:  J Fungi (Basel)       Date:  2021-12-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.