Literature DB >> 25847667

Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures.

Emran Mohammad Abu Anas1, Alexander Seitel, Abtin Rasoulian, Paul St John, David Pichora, Kathryn Darras, David Wilson, Victoria A Lessoway, Ilker Hacihaliloglu, Parvin Mousavi, Robert Rohling, Purang Abolmaesumi.   

Abstract

PURPOSE: The scaphoid bone is the most frequently fractured bone in the wrist. When fracture fixation is indicated, a screw is inserted into the bone either in an open surgical procedure or percutaneously under fluoroscopic guidance. Due to the complex geometry of the wrist, fracture fixation is a challenging task. Fluoroscopic guidance exposes both the patient and the physician to ionizing radiation. Ultrasound-based guidance has been suggested as a real-time, radiation-free alternative. The main challenge of using ultrasound is the difficulty in interpreting the images due to the low contrast and noisy nature of the data.
METHODS: We propose a bone enhancement method that exploits local spectrum features of the ultrasound image. These features are utilized to design a set of quadrature band-pass filters and subsequently estimate the local phase symmetry, where high symmetry is expected at the bone locations. We incorporate the shadow information below the bone surfaces to further enhance the bone responses. The extracted bone surfaces are then used to register a statistical wrist model to ultrasound volumes, allowing the localization and interpretation of the scaphoid bone in the volumes.
RESULTS: Feasibility experiments were performed using phantom and in vivo data. For phantoms, we obtain a surface distance error 1.08 mm and an angular deviation from the main axis of the scaphoid bone smaller than 5°, which are better compared to previously presented approaches.
CONCLUSION: The results are promising for further development of a surgical guidance system to enable accurate anatomy localization for guiding percutaneous scaphoid fracture fixations.

Entities:  

Mesh:

Year:  2015        PMID: 25847667     DOI: 10.1007/s11548-015-1181-6

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  23 in total

1.  Automatic detection of lumbar anatomy in ultrasound images of human subjects.

Authors:  Denis Tran; Robert N Rohling
Journal:  IEEE Trans Biomed Eng       Date:  2010-05-10       Impact factor: 4.538

2.  Cadaver validation of intensity-based ultrasound to CT registration.

Authors:  G P Penney; D C Barratt; C S K Chan; M Slomczykowski; T J Carter; P J Edwards; D J Hawkes
Journal:  Med Image Anal       Date:  2006-03-07       Impact factor: 8.545

3.  Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model.

Authors:  Abtin Rasoulian; Robert Rohling; Purang Abolmaesumi
Journal:  IEEE Trans Med Imaging       Date:  2013-06-12       Impact factor: 10.048

4.  Automatic adaptive parameterization in local phase feature-based bone segmentation in ultrasound.

Authors:  Ilker Hacihaliloglu; Rafeef Abugharbieh; Antony J Hodgson; Robert N Rohling
Journal:  Ultrasound Med Biol       Date:  2011-08-06       Impact factor: 2.998

5.  Integration of local and global features for anatomical object detection in ultrasound.

Authors:  Bahbibi Rahmatullah; Aris T Papageorghiou; J Alison Noble
Journal:  Med Image Comput Comput Assist Interv       Date:  2012

6.  Local phase tensor features for 3-D ultrasound to statistical shape+pose spine model registration.

Authors:  Ilker Hacihaliloglu; Abtin Rasoulian; Robert N Rohling; Purang Abolmaesumi
Journal:  IEEE Trans Med Imaging       Date:  2014-06-26       Impact factor: 10.048

7.  Automatic bone localization and fracture detection from volumetric ultrasound images using 3-D local phase features.

Authors:  Ilker Hacihaliloglu; Rafeef Abugharbieh; Antony J Hodgson; Robert N Rohling; Pierre Guy
Journal:  Ultrasound Med Biol       Date:  2011-11-21       Impact factor: 2.998

Review 8.  Ligamentous injuries of the wrist.

Authors:  S W Meldon; S W Hargarten
Journal:  J Emerg Med       Date:  1995 Mar-Apr       Impact factor: 1.484

9.  Time off work due to scaphoid fractures and other carpal injuries in The Netherlands in the period 1990 to 1993.

Authors:  A B van der Molen; J W Groothoff; G J Visser; P H Robinson; W H Eisma
Journal:  J Hand Surg Br       Date:  1999-04

Review 10.  Scaphoid nonunion: diagnosis and treatment.

Authors:  Victoria S Pao; James Chang
Journal:  Plast Reconstr Surg       Date:  2003-11       Impact factor: 4.730

View more
  5 in total

Review 1.  Computer-assisted Surgery for Scaphoid Fracture.

Authors:  Zi-Run Xiao; Ge Xiong
Journal:  Curr Med Sci       Date:  2018-12-07

2.  Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

Authors:  Ilker Hacihaliloglu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-11       Impact factor: 2.924

3.  Ultrasound imaging and segmentation of bone surfaces: A review.

Authors:  Ilker Hacihaliloglu
Journal:  Technology (Singap World Sci)       Date:  2017-03-31

4.  Registration of a statistical model to intraoperative ultrasound for scaphoid screw fixation.

Authors:  Emran Mohammad Abu Anas; Alexander Seitel; Abtin Rasoulian; Paul St John; Tamas Ungi; Andras Lasso; Kathryn Darras; David Wilson; Victoria A Lessoway; Gabor Fichtinger; Michelle Zec; David Pichora; Parvin Mousavi; Robert Rohling; Purang Abolmaesumi
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-16       Impact factor: 2.924

5.  Three-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint.

Authors:  Nazlı Tümer; Aimee C Kok; Frans M Vos; Geert J Streekstra; Christian Askeland; Gabrielle J M Tuijthof; Amir A Zadpoor
Journal:  Sensors (Basel)       Date:  2018-07-21       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.