Literature DB >> 25844588

In vitro and in situ characterization of arthroscopic loop security and knot security of braided polyblend sutures: a biomechanical study.

Lucas C Armstrong, Alexander Chong1, Ryan W Livermore, Daniel J Prohaska, Amanda N Doyon, Paul H Wooley.   

Abstract

We conducted a study to evaluate biomechanical performance during destructive testing of several different suture materials in various arthroscopic knot configurations under both in vitro and in situ conditions. Surgeons of different levels of experience tied the knots. Three different arthroscopic knots (static surgeon's, Weston, Tennessee slider) with 3 reverse half-hitches on alternating posts were tested using Fiberwire, ForceFiber, Orthocord, and Ultrabraid suture materials under both in vitro and in situ (blood plasma at 37°C) conditions. Three surgeons of different experience levels tied the knots on a post 30 mm in circumference. A single load-to-failure test was performed. There were no significant in vitro-in situ differences for Ultrabraid in the different knot configurations or with the different experience levels. Surgeon B (intermediate experience) showed no significant differences between test conditions for any knot configuration or suture material. With Tennessee slider knots, surgeon C (least experience) showed significantly lower clinical failure load under both test conditions and had a higher percentage of complete knot slippage. Surgeon B had no knot slippage with use of Fiberwire. Both the aqueous environment and the surgeon's familiarity with certain knots have an effect on knot security.

Mesh:

Year:  2015        PMID: 25844588

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  4 in total

1.  A Biomechanical Comparison of Varying Base Knot Configurations with Different Overhand/Underhand Combinations of Reversing Half-Hitches on Alternating Posts After Basic Instructional Training.

Authors:  Heather A Evin; Tyler T Bilden; Benjamin C Noonan; Alexander Cm Chong
Journal:  Iowa Orthop J       Date:  2019

2.  The Effect of Different Combinations of Three Stacked Half-Hitches and Suture Materials on an Arthroscopic Knot in a Dry or Wet Environment.

Authors:  Alexander Cm Chong; Jordan L Ochs; Rosalee E Zackula; Lisa N MacFadden; Daniel J Prohaska
Journal:  Iowa Orthop J       Date:  2018

3.  Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity.

Authors:  Alexander Cm Chong; Daniel J Prohaska; Brian P Bye
Journal:  Kans J Med       Date:  2017-05-15

4.  Comparing the Influence of Different Overhand/Underhand Stacking Combinations of Reversing Half-Hitches on Alternating Posts on Arthroscopic Knot Security.

Authors:  Tyler T Bilden; Heather A Evin; Benjamin C Noonan; Alexander C M Chong
Journal:  Kans J Med       Date:  2019-11-25
  4 in total