Margin Reflex Distance: Differences Based on Camera and Flash Positions.

Catherine J Choi1, Jonathan C Chou, Daniel R Lefebvre, Michael K Yoon.   

Abstract

PURPOSE: To evaluate the effect of camera flash position on the measurement of photographic margin reflex distances (MRD).
METHODS: Subjects without any ophthalmic disease were prospectively enrolled after institutional review board approval. Clinical measurements of MRD1 and interpalpebral fissure were obtained. Photographs were then taken with a digital single lens reflex with built-in pop-up flash (dSLR-pop), a dSLR with lens-mounted ring flash (dSLR-ring), a point-and-shoot camera, and a smartphone, each in 4 positions: with the camera upright, rotated 90°, 180°, and 270°. The images were analyzed using ImageJ software to measure MRD1, interpalpebral fissure, horizontal white-to-white, and distance from nasal limbus to the corneal light reflex.
RESULTS: Thirty-two eyes of 16 subjects were included (ages 27-65). When using the dSLR-ring, point-and-shoot, and smartphone, the difference between clinical and photographic MRD1 did not reach statistical significance. There was, however, a statistically significant difference in the upright position with dSLR-pop (mean difference 0.703 mm, σ = 0.984 mm, p = 0.0008). For dSLR-pop, photographic MRD1 in upright versus inverted position differed significantly (mean difference -0.562 mm, σ =0.348 mm, p < 0.0001). Photographic MRD1 between dSLR-pop and dSLR-ring showed significant difference in upright position (mean difference -0.572 mm, σ = 0.701 mm, p = 0.0002). There were no statistically significant differences between clinical and photographic interpalpebral fissure, and among white-to-white and nasal limbus to light reflex measurements in any position in all 4 cameras.
CONCLUSIONS: When using photographs for measurement of MRD1, cameras with a near-coaxial light source and aperture have values that are most similar to clinical measurements.

Entities:  

Mesh:

Year:  2016        PMID: 25844505     DOI: 10.1097/IOP.0000000000000456

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  5 in total

1.  A novel method to measure margin reflex distance using the autorefractometer.

Authors:  Demet Yolcu; Sibel Ozdogan
Journal:  Int Ophthalmol       Date:  2021-11-05       Impact factor: 2.031

Review 2.  Clinically useful smartphone ophthalmic imaging techniques.

Authors:  Amar Pujari; Gunjan Saluja; Divya Agarwal; Harathy Selvan; Namrata Sharma
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-09-11       Impact factor: 3.117

3.  Ten Years of Results of Modified Frontalis Muscle Transfer for the Correction of Blepharoptosis.

Authors:  Woo Jeong Kim; Dae Hwan Park; Dong Gil Han
Journal:  Arch Plast Surg       Date:  2016-03-18

4.  Efficacy of Gaze Photographs in Diagnosing Ocular Myasthenia Gravis.

Authors:  Jeeyun Ahn; Kyung Seok Park; Ji Soo Kim; Jeong Min Hwang
Journal:  J Clin Neurol       Date:  2018-05-31       Impact factor: 3.077

5.  Application of Second-Generation Swept-Source Anterior Segment-OCT in the Measurement of Marginal Reflex Distance-1 (MRD-1).

Authors:  Kosuke Ogasawara
Journal:  Clin Ophthalmol       Date:  2020-03-03
  5 in total