Literature DB >> 2584380

Visuwell Reagin, a non-treponemal enzyme-linked immunosorbent assay for the serodiagnosis of syphilis.

T J White1, S A Fuller.   

Abstract

A urease-based enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of reagin antibodies in serum. Visuwell Reagin (ADI Diagnostics Inc., Rexdale, Ontario, Canada) is a non-treponemal screening test for the serodiagnosis of syphilis which has the benefits of large batch testing, automatability, and objective interpretation of results. Unheated, undiluted sera are incubated in 96-well microtiter plates coated with a modified cardiolipin-lecithin-cholesterol antigen. Antibody bound to the plate is detected by an anti-human immunoglobulin G-urease conjugate. The procedure consists of three steps, with a total test time of 60 min. Visuwell Reagin ELISA was compared with the Venereal Disease Research Laboratory (VDRL) test and the reagin screening test (RST) with the following results. For ELISA versus the VDRL test, the sensitivities for untreated syphilis (n = 37) were 97.3% for both ELISA and the VDRL test, the confirmatory positive values (n = 79) were 84.8% for ELISA and 72.2% for the VDRL test, and the specificities for normal samples (n = 1,327) were 98.8% for ELISA and 99.5% for the VDRL test. For ELISA versus RST, the sensitivities for untreated syphilis (n = 57) were 94.7% for ELISA and 87.7% for RST, the confirmatory positive values (n = 26) were 96.2% for ELISA and 92.3% for RST, and the specificities for normal samples (n = 1,891) were 99.6% for ELISA and 99.3% for RST. The overall concordance values of ELISA with VDRL test and RST were 96.7 and 97.9%, respectively. The specificity of ELISA compared with that of RST may be underestimated, since confirmatory data were not available for all apparent false-positive samples. Visuwell Reagin had increased sensitivity and similar specificity compared with flocculation tests.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2584380      PMCID: PMC267013          DOI: 10.1128/jcm.27.10.2300-2304.1989

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Rapid plasma reagin card test for syphilis and other treponematoses.

Authors:  J PORTNOY; J H BREWER; A HARRIS
Journal:  Public Health Rep       Date:  1962-08       Impact factor: 2.792

Review 2.  Enzyme-immunoassay.

Authors:  A H Schuurs; B K Van Weemen
Journal:  Clin Chim Acta       Date:  1977-11-15       Impact factor: 3.786

3.  Comparison of an enzyme-linked immunoassay with an indirect hemagglutination assay for the detection of antibodies to cytomegalovirus.

Authors:  R Chairez; J B Schleicher; A J Cesario
Journal:  J Virol Methods       Date:  1984-10       Impact factor: 2.014

4.  An investigation of the use of urease-antibody conjugates in enzyme immunoassays.

Authors:  H M Chandler; J C Cox; K Healey; A MacGregor; R R Premier; J G Hurrell
Journal:  J Immunol Methods       Date:  1982-09-17       Impact factor: 2.303

5.  Unheated serum reagin test as a quantitative test for syphilis.

Authors:  D E Pettit; S A Larsen; V Pope; M W Perryman; M R Adams
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

6.  The reagin screen test: a new reagin card test for syphilis.

Authors:  R W March; G E Stiles
Journal:  Sex Transm Dis       Date:  1980 Apr-Jun       Impact factor: 2.830

7.  Toluidine red unheated serum test, a nontreponemal test for syphilis.

Authors:  D E Pettit; S A Larsen; P S Harbec; J C Feeley; C E Parham; D D Cruce; E A Hambie; M W Perryman
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

8.  Enzyme-linked immunosorbent assay for detection of antibodies to the venereal disease research laboratory (VDRL) antigen in syphilis.

Authors:  N S Pedersen; O Orum; S Mouritsen
Journal:  J Clin Microbiol       Date:  1987-09       Impact factor: 5.948

  8 in total
  4 in total

1.  Capture-S, a nontreponemal solid-phase erythrocyte adherence assay for serological detection of syphilis.

Authors:  D L Stone; M C Moheng; S Rolih; L T Sinor
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

Review 2.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

3.  Blood spot screening and confirmatory tests for syphilis antibody.

Authors:  R Stevens; K Pass; S Fuller; A Wiznia; L Noble; S Duva; M Neal
Journal:  J Clin Microbiol       Date:  1992-09       Impact factor: 5.948

4.  Syphilis Laboratory Guidelines: Performance Characteristics of Nontreponemal Antibody Tests.

Authors:  Susan Tuddenham; Samantha S Katz; Khalil G Ghanem
Journal:  Clin Infect Dis       Date:  2020-06-24       Impact factor: 9.079

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.