Literature DB >> 25838388

MRI RF array decoupling method with magnetic wall distributed filters.

Ian R O Connell, Kyle M Gilbert, Mohamed A Abou-Khousa, Ravi S Menon.   

Abstract

Multi-channel radio-frequency (RF) transmit coil arrays have been developed to mitigate many of the RF challenges associated with ultra-high field ( ≥ 7T) magnetic resonance imaging (MRI). These arrays can be used for parallel RF transmission to produce spatially tailored RF excitation over the field of view. However, the realization of such arrays remains a challenge due to significant reactive interaction between the array coils, i.e., mutual coupling. In this paper, a novel bandstop filter ("magnetic wall") is used in an MRI RF transmit array to decouple individual coils. The proposed decoupling method is inspired by periodic resonator designs commonly used in frequency selective surfaces and is used as a distributed RF filter to suppress the transmission of RF energy between coils in an array. The decoupling of the magnetic wall (MW) is analyzed in terms of equivalent circuits that include terms for both magnetic and electric coupling for an arbitrary number of MW resonant conductors. Both frequency-and time-domain full-wave simulations were performed to analyze a specific MW structure. The performance of the proposed method is experimentally validated for both first-order coupling and higher-order coupling with a three-coil 7T array setup. Analysis and measurements confirm that the rejection band of the MW can be tuned to provide high isolation in the presence of cross coupling between RF array coils.

Mesh:

Year:  2015        PMID: 25838388     DOI: 10.1109/TMI.2014.2378695

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI.

Authors:  Xinqiang Yan; Zhipeng Cao; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-02-29       Impact factor: 0.831

2.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

3.  High-resolution probe design for measuring the dielectric properties of human tissues.

Authors:  Xinran Wang; Hongfu Guo; Chen Zhou; Junkai Bai
Journal:  Biomed Eng Online       Date:  2021-08-28       Impact factor: 2.819

4.  Magnetic metasurfaces properties in the near field regions.

Authors:  Danilo Brizi; Agostino Monorchio
Journal:  Sci Rep       Date:  2022-02-28       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.