Literature DB >> 25837423

Quantification of Left Ventricular Linear, Areal and Volumetric Dimensions: A Phantom and in Vivo Comparison of 2-D and Real-Time 3-D Echocardiography with Cardiovascular Magnetic Resonance.

Christian L Polte1, Kerstin M Lagerstrand2, Sinsia A Gao3, Carl R Lamm4, Odd Bech-Hanssen5.   

Abstract

Two-dimensional echocardiography and real-time 3-D echocardiography have been reported to underestimate human left ventricular volumes significantly compared with cardiovascular magnetic resonance. We investigated the ability of 2-D echocardiography, real-time 3-D echocardiography and cardiovascular magnetic resonance to delineate dimensions of increasing complexity (diameter-area-volume) in a multimodality phantom model and in vivo, with the aim of elucidating the main cause of underestimation. All modalities were able to delineate phantom dimensions with high precision. In vivo, 2-D and real-time 3-D echocardiography underestimated short-axis end-diastolic linear and areal and all left ventricular volumetric dimensions significantly compared with cardiovascular magnetic resonance, but not short-axis end-systolic linear and areal dimensions. Underestimation increased successively from linear to volumetric left ventricular dimensions. When analyzed according to the same principles, 2-D and real-time 3-DE echocardiography provided similar left ventricular volumes. In conclusion, echocardiographic underestimation of left ventricular dimensions is due mainly to inherent technical differences in the ability to differentiate trabeculated from compact myocardium. Identical endocardial border definition criteria are needed to minimize differences between the modalities and to ensure better comparability in clinical practice.
Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  2-D echocardiography; Cardiovascular magnetic resonance; Left ventricular dimensions; Real-time 3-D echocardiography

Mesh:

Year:  2015        PMID: 25837423     DOI: 10.1016/j.ultrasmedbio.2015.03.001

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Optimization of the method of measuring left ventricular end-diastolic diameter in cardiac magnetic resonance as a predictor of left ventricular enlargement.

Authors:  Paweł Gać; Łukasz Waszczuk; Jacek Kurcz; Rafał Poręba
Journal:  Sci Rep       Date:  2022-05-19       Impact factor: 4.996

2.  Cardiac and respiratory-gated volumetric murine ultrasound.

Authors:  Arvin H Soepriatna; Frederick W Damen; Pavlos P Vlachos; Craig J Goergen
Journal:  Int J Cardiovasc Imaging       Date:  2017-12-12       Impact factor: 2.357

3.  An Optimistic View towards the Real Time 3D Echocardiography in Congenital Heart Disease: A Simple 'Crop Box' Should Give an Infinite Information in the Near Future!

Authors:  Jin-Hee Oh
Journal:  J Cardiovasc Ultrasound       Date:  2016-06-22
  3 in total