Literature DB >> 25836695

Patient grouping for dose surveys and establishment of diagnostic reference levels in paediatric computed tomography.

J Vassileva1, M Rehani2.   

Abstract

There has been confusion in literature on whether paediatric patients should be grouped according to age, weight or other parameters when dealing with dose surveys. The present work aims to suggest a pragmatic approach to achieve reasonable accuracy for performing patient dose surveys in countries with limited resources. The analysis is based on a subset of data collected within the IAEA survey of paediatric computed tomography (CT) doses, involving 82 CT facilities from 32 countries in Asia, Europe, Africa and Latin America. Data for 6115 patients were collected, in 34.5 % of which data for weight were available. The present study suggests that using four age groups, <1, >1-5, >5-10 and >10-15 y, is realistic and pragmatic for dose surveys in less resourced countries and for the establishment of DRLs. To ensure relevant accuracy of results, data for >30 patients in a particular age group should be collected if patient weight is not known. If a smaller sample is used, patient weight should be recorded and the median weight in the sample should be within 5-10 % from the median weight of the sample for which the DRLs were established. Comparison of results from different surveys should always be performed with caution, taking into consideration the way of grouping of paediatric patients. Dose results can be corrected for differences in patient weight/age group.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 25836695     DOI: 10.1093/rpd/ncv113

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  8 in total

Review 1.  Review of the current status of radiation protection in diagnostic radiology in Africa.

Authors:  Wilbroad Muhogora; Madan M Rehani
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-12

2.  Individual radiation exposure from computed tomography: a survey of paediatric practice in French university hospitals, 2010-2013.

Authors:  Neige M Y Journy; Serge Dreuil; Nathalie Boddaert; Jean-François Chateil; Didier Defez; Hubert Ducou-le-Pointe; Jean-Marc Garcier; Joël Guersen; Bouchra Habib Geryes; Andreas Jahnen; Choonsik Lee; Jacqueline Payen-de-la-Garanderie; Jean-Pierre Pracros; Dominique Sirinelli; Isabelle Thierry-Chef; Marie-Odile Bernier
Journal:  Eur Radiol       Date:  2017-08-23       Impact factor: 5.315

3.  Radiation dose optimisation for conventional imaging in infants and newborns using automatic dose management software: an application of the new 2013/59 EURATOM directive.

Authors:  L Alejo; E Corredoira; F Sánchez-Muñoz; C Huerga; Z Aza; R Plaza-Núñez; A Serrada; M Bret-Zurita; M Parrón; C Prieto-Areyano; G Garzón-Moll; R Madero; E Guibelalde
Journal:  Br J Radiol       Date:  2018-04-09       Impact factor: 3.039

4.  Use of weight-based vs age-based groupings in the study of typical values of air kerma area product (PKA) for paediatric radiographs of chest and abdomen.

Authors:  Ioannis Delakis; Charlotte Kelly
Journal:  Br J Radiol       Date:  2021-09-19       Impact factor: 3.039

5.  Long-term experience and analysis of data on diagnostic reference levels: the good, the bad, and the ugly.

Authors:  Patrice Roch; David Célier; Cécile Dessaud; Cécile Etard; Madan M Rehani
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

6.  Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea.

Authors:  Jae Yeon Hwang; Young Hun Choi; Hee Mang Yoon; Young Jin Ryu; Hyun Joo Shin; Hyun Gi Kim; So Mi Lee; Sun Kyung You; Ji Eun Park
Journal:  Korean J Radiol       Date:  2021-04-01       Impact factor: 3.500

7.  Paediatric diagnostic reference levels for common radiological examinations using the European guidelines.

Authors:  Anja Almén; Jónína Guðjónsdóttir; Nils Heimland; Britta Højgaard; Hanne Waltenburg; Anders Widmark
Journal:  Br J Radiol       Date:  2021-12-13       Impact factor: 3.039

8.  Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables.

Authors:  Yusuke Inoue; Hiroyasu Itoh; Anri Waga; Ryosuke Sasa; Kohei Mitsui
Journal:  Tomography       Date:  2022-04-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.