Literature DB >> 25836656

Retinal Nerve Fiber Layer Thickness Measurement Repeatability for Cirrus HD-OCT Retinal Tracking System During Eye Movement.

Young Hoon Hwang1, Miryoung Song, Dai Woo Kim, Ki Bang Uhm.   

Abstract

PURPOSE: To investigate the repeatability of peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained using Cirrus high-definition optical coherence tomographic (Cirrus HD-OCT) retinal tracking system during various types of eye movements.
MATERIALS AND METHODS: We included 20 healthy eyes, 40 glaucomatous eyes of elderly patients, and 17 eyes with pathologic nystagmus. For healthy eyes, RNFL thickness measurements were obtained under 3 conditions: (1) without eye movement, fixated on the device's internal target, (2) with horizontal eye movement, and (3) with vertical eye movement during scan acquisition. Each session was performed 3 times with and without the use of the retinal tracking system. The repeatability of RNFL thickness measurements obtained with and without the retinal tracking was compared within each session and among the sessions.
RESULTS: In healthy eyes, measurements obtained without the use of a retinal tracking system showed lower repeatability when measurements were obtained with eye movements than without (P<0.05). However, when retinal tracking system was used, measurement repeatability under conditions with eye movements was similar to that achieved without eye movement (P>0.05) and higher than that obtained without the use of a retinal tracking system (P<0.05). In elderly glaucomatous patients, the retinal tacking system did not significantly improve measurement repeatability during fixation (P>0.05). In eyes with pathologic nystagmus, the tracking system did not follow eye movement and scan acquisition was not processed.
CONCLUSIONS: Cirrus HD-OCT retinal tracking system may enhance RNFL thickness measurement repeatability under certain, but not all, eye movement conditions.

Entities:  

Mesh:

Year:  2016        PMID: 25836656     DOI: 10.1097/IJG.0000000000000250

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  4 in total

1.  Effect of head tilt on repeatability of optic nerve head parameters using cirrus spectral-domain optical coherence tomography.

Authors:  Lilian Hui Li Koh; Muhammad Amir Ismail; Sae Cheong Yap; Elizabeth Poh Ying Wong; Leonard Wei Leon Yip
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

Review 2.  Factors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples.

Authors:  Joshua S Hardin; Giovanni Taibbi; Seth C Nelson; Diana Chao; Gianmarco Vizzeri
Journal:  J Ophthalmol       Date:  2015-08-13       Impact factor: 1.909

3.  Evaluation of a Qualitative Approach for Detecting Glaucomatous Progression Using Wide-Field Optical Coherence Tomography Scans.

Authors:  Zhichao Wu; Denis S D Weng; Rashmi Rajshekhar; Abinaya Thenappan; Robert Ritch; Donald C Hood
Journal:  Transl Vis Sci Technol       Date:  2018-05-01       Impact factor: 3.283

4.  Generating large field of view en-face projection images from intra-acquisition motion compensated volumetric optical coherence tomography data.

Authors:  Florian Schwarzhans; Sylvia Desissaire; Stefan Steiner; Michael Pircher; Christoph K Hitzenberger; Hemma Resch; Clemens Vass; Georg Fischer
Journal:  Biomed Opt Express       Date:  2020-11-04       Impact factor: 3.732

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.